Three dimensional Monte Carlo code for photon migration through complex heterogeneous media including the adult human head.

نویسندگان

  • David Boas
  • J Culver
  • J Stott
  • A Dunn
چکیده

We describe a novel Monte Carlo code for photon migration through 3D media with spatially varying optical properties. The code is validated against analytic solutions of the photon diffusion equation for semi-infinite homogeneous media. The code is also cross-validated for photon migration through a slab with an absorbing heterogeneity. A demonstration of the utility of the code is provided by showing time-resolved photon migration through a human head. This code, known as 'tMCimg', is available on the web and can serve as a resource for solving the forward problem for complex 3D structural data obtained by MRI or CT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Monte Carlo Assessment of Photon Organ Doses from 222Rn Progeny in Adult ORNL Phantom

Introduction The potential hazards posed by exposure to radiation from radon have been of great concern worldwide, since it is especially associated with increased risk of lung cancer. Some radioisotopes of radon progeny deposited in the human lungs emit β particles followed by the γ rays. While γ rays are comparatively less damaging to the respiratory system than α and β particles, it is the p...

متن کامل

A comparative Monte Carlo study on 6MV photon beam characteristics of Varian 21EX and Elekta SL-25 linacs

Background: Monte Carlo method (MC) has played an important role in design and optimization of medical linacs head and beam modeling. The purpose of this study was to compare photon beam features of two commercial linacs, Varian 21EX and Elekta SL-25 using MCNP4C MC code. Materials and Methods: The 6MV photon beams of Varian 21EX and Elekta Sl-25 linacs were simulated based on manufacturers pro...

متن کامل

An assessment of the Photon Contamination due to Bremsstrahlung Radiation in the Electron Beams of a NEPTUN 10PC Linac using a Monte Carlo Method

Introduction: In clinical electron beams, most of bremsstrahlung radiation is produced by various linac head structures. This bremsstrahlung radiation dose is influenced by the geometry and construction of every component of the linac treatment head structures. Thus, it can be expected that the amount of the contaminated photon dose due to bremsstrahlung radiation varies among different linacs,...

متن کامل

Benchmarking of Monte Carlo model of 6 Mv photon beam produced by Siemens Oncor® linear accelerator: determination of initial electron beam parameters in comparison with measurement

Introduction: The aim of this study was to investigate the initial electron beam parameters for Monte Carlo model of 6MV photon beam produced by Siemens Oncor® linear accelerator.   Materials and Methods: In this study, the EGSnrc Monte Carlo user codes BEAMnrc and DOSXYZnrc were used. The beamnrc code were used for modelling of a 6 MV photon beam produced by...

متن کامل

Dose Calculations for Lung Inhomogeneity in High-Energy Photon Beams and Small Beamlets: A Comparison between XiO and TiGRT Treatment Planning Systems and MCNPX Monte Carlo Code

Introduction Radiotherapy with small fields is used widely in newly developed techniques. Additionally, dose calculation accuracy of treatment planning systems in small fields plays a crucial role in treatment outcome. In the present study, dose calculation accuracy of two commercial treatment planning systems was evaluated against Monte Carlo method. Materials and Methods Siemens Once or linea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics express

دوره 10 3  شماره 

صفحات  -

تاریخ انتشار 2002