Importance of standardization of lipase assays by using appropriate calibrators.

نویسندگان

  • J M Lessinger
  • J L Dourson
  • G Férard
چکیده

Comparability of lipase catalytic activities was poor when lipase was determined in 50 patients' specimens by a turbidimetric (Boehringer) and a colorimetric (Sigma) assay. Mean values of results differed by a ratio of 2.39. Optimal common conditions were defined for the titration of lipase activity in two commercial calibrators and in a home-purified preparation of human pancreatic lipase (HPL). When using these titers for each calibrator, comparability was greatly improved (ratio = 1.25). This result indicates that a significant part of between-method discrepancy is due to the lack of a reference method for the titration of lipase calibrators. Intermethod behavior of each material was compared with that of patients' specimens. By using HPL as calibrator, comparability was still dramatically improved (ratio = 1.01). This study shows the importance of the validation of a material for defined routine measurement procedures, before its use as calibrator.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Uncertainty calculation for calibrators of the IFCC HbA1c standardization network

S. Schubert University of Ulm, Department of Mathematics and Economics, Helmholtzstraße 18, 89069 Ulm, Germany C. Weykamp · C. Siebelder Queen Beatrix Hospital, Beatrix Park 1, 7101 BN, Winterswijk, The Netherlands Abstract Within the last decade, the IFCC HbA1c standardization network has established the metrologically highest reference measurement procedure for HbA1c testing. Based on this pr...

متن کامل

Minimizing interlaboratory variation in routine assays of serum cholesterol through the use of serum calibrators.

A cholesterol standardization program was developed in The Netherlands for clinical laboratories that use their analytical results as indicators of cardiovascular risk. Participants with sufficient precision but inaccurate results are encouraged to use serum-based calibrators as a means to decrease bias. A regional pilot survey and thereafter a national one were carried out in 31 and 138 labora...

متن کامل

Standardization for four protein analytes with the Behring Nephelometer.

Owing to the generally higher values observed in the initial establishment of immunoglobulins (Ig) G, A, and M assays with the Behring Nephelometer, we elected to verify five commercial protein calibrators. This initial verification was performed by standardizing the Behring Nephelometer with the World Health Organization (WHO) International Reference Preparation for Human Serum Immunoglobulins...

متن کامل

An investigation on the performance of dose calibrators in nuclear medicine centers in Iran

Background: To investigate the status of the nuclear medicine (NM) centers in Iran for the performance of dose calibrators, 18 out of 54 centers providing NM services in Iran were randomly selected and inspected in 1997. In the first phase of the study the selected centers were inspected for performing of quality control (QC) tests of dose calibrators. The linearity of the activity res...

متن کامل

A soluble fibrin standard: comparable dose-response with immunologic and functional assays.

A soluble fibrin (SF) preparation has been developed as a potential standard by the Scientific and Standardization Committee for use in assays evaluating in vitro preparations and patient plasma samples. The SF standard was prepared by reaction of factor XIII-free fibrinogen with thrombin, followed by neutralization with hirudin and solubilization of the fibrin in acetic acid. As characterized ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 42 12  شماره 

صفحات  -

تاریخ انتشار 1996