Thrombus formation on a defibrillator lead with conductor externalization
نویسندگان
چکیده
A 51 year old man with arrhythmogenic right ventricular cardiomyopathy reported non-specific symptoms of muscle aches and shivering at outpatient review. A dual chamber implantable cardioverter defibrillator (ICD) had been inserted seven years previously. Fluoroscopic lead screening had previously demonstrated conductor externalisation (Figure and Video) of a single coil Riata ICD lead (model number 1582-65, St. Jude Medical, Sylmar, CA, USA). All electrical parameters were normal. Supplementary data related to this article can be found online at http://dx.doi.org/10.1016/j.ipej.2015.07.014.
منابع مشابه
Fluoroscopic investigation of Riata® transvenous defibrillator leads.
BACKGROUND Implantable cardioverter-defibrillator leads from Riata® family (St. Jude Medical Inc., Sylmar, CA, USA) have been recently recalled by Food and Drug Administration for concerns of a unique type of "inside-out" insulation failure leading to conductor externalization. The objective of this study was to evaluate the prevalence and predictors of conductor externalization in patients imp...
متن کاملExternalized conductors and insulation failure in Biotronik defibrillator leads: History repeating or a false alarm?
Conductor externalization and insulation failure are frequent complications with the recalled St. Jude Medical Riata implantable cardioverter-defibrillator (ICD) leads. Conductor externalization is a "unique" failure mechanism: Cables externalize through the insulation ("inside-out" abrasion) and appear outside the lead body. Recently, single reports described a similar failure also for Biotron...
متن کاملRepetitive inappropriate implantable cardioverter-defibrillator shocks due to insulation failure with externalized conductor cables of a Biotronik Linox SD ICD lead.
We report the case of a 54-year-old patient with repetitive inappropriate implantable cardioverter-defibrillator (ICD) shocks due to externalized pace-sense conductor cables of a Biotronik Linox SD 65/16 ICD lead. This case report is one of few in the literature describing inappropriate shocks due to insulation failure with externalization of conductor cables of an ICD lead from the Biotronik L...
متن کاملPrevalence and presentation of externalized conductors and electrical abnormalities in Riata defibrillator leads after fluoroscopic screening: report from the Netherlands Heart Rhythm Association Device Advisory Committee.
BACKGROUND The Riata family of implantable cardioverter-defibrillator (ICD) leads is prone to a specific insulation abrasion characterized by externalization of conductor cables. The objective of this study was to determine the prevalence of externalized conductors and electrical abnormalities in Riata ICD leads by fluoroscopic screening and standard ICD interrogation. METHODS AND RESULTS All...
متن کاملCombined LASER and femoral approach to remove a previous failure of Riata lead extraction
Transvenous extraction of Riata lead could be a challenging procedure due to insulation failure and conductor cables' externalization through the eroded outer insulation. In this case, a complete lead extraction was achieved through a combined LASER and femoral approach because of the massive conductors' externalization.