Local seismic network for monitoring of a potential nuclear power plant area

نویسندگان

  • Timo Tiira
  • Marja Uski
  • Jari Kortström
  • Outi Kaisko
  • Annakaisa Korja
چکیده

This study presents a plan for seismic monitoring of a region around a potential nuclear power plant. Seismic monitoring is needed to evaluate seismic risk. The International Atomic Energy Agency has set guidelines on seismic hazard evaluation and monitoring of such areas. According to these guidelines, we have made a plan for a local network of seismic stations to collect data for seismic source characterization and seismotectonic interpretations, as well as to monitor seismic activity and natural hazards. The detection and location capability of the network were simulated using different station configurations by computing spatial azimuthal coverages and detection threshold magnitudes. Background noise conditions around Pyhäjoki were analyzed by comparing data from different stations. The annual number of microearthquakes that should be detected with a dense local network centered around Pyhäjoki was estimated. The network should be dense enough to fulfill the requirements of azimuthal coverage better than 180° and automatic event location capability down to ML ∼ 0 within a distance of 25 km from the site. A network of 10 stations should be enough to reach these goals. With this setup, the detection threshold magnitudes are estimated to be ML = -0.1 and ML = 0.1 within a radius of 25 and 50 km from Pyhäjoki, respectively. The annual number of earthquakes detected by the network is estimated to be 2 (ML ≥ ∼ -0.1) within 25 km radius and 5 (ML ≥ ∼-0.1 to ∼0.1) within 50 km radius. The location accuracy within 25 km radius is estimated to be 1-2 and 4 km for horizontal coordinates and depth, respectively. Thus, the network is dense enough to map out capable faults with horizontal accuracy of 1-2 km within 25 km radius of the site. The estimation is based on the location accuracies of five existing networks in northern Europe. Local factors, such as seismic noise sources, geology and infrastructure might limit the station configuration and detection and location capability of the network.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automatic data processing and analysis system for monitoring region around a planned nuclear power plant

The Institute of Seismology of University of Helsinki is building a new local seismic network, called OBF network, around planned nuclear power plant in Northern Ostrobothnia, Finland. The network will consist of nine new stations and one existing station. The network should be dense enough to provide azimuthal coverage better than 180 and automatic detection capability down to ML −0.1 within a...

متن کامل

Seismic Risk Assessment of Power Substations

Power networks are among the most important infrastructures that without them, industrial, economic and social procedures will halt. Therefore, they should be planned for the most difficult conditions to provide services with minimum disruption. Power substations are of great importance to a power network, because any disruption in their components can produce extensive problems through the net...

متن کامل

Radon monitoring in gas turbine and thermal power station A comparative study

Background: In this study, measurement of indoor radon and its progeny levels was carried out in Gas Turbine Power Station in Haryana ( India ), where natural gas is used as fuel. For comparison, the results of a study carried out in thermal power plant in Haryana are also presented. Radon being a ubiquitous air pollutant has global impact and its monitoring in the environment at work places is...

متن کامل

Fukushima nuclear power plant area

High-resolution tomographic images of the crust and upper mantle in and around the area of the 2011 Iwaki earthquake (M 7.0) and the Fukushima nuclear power plant are determined by inverting a large number of high-quality arrival times with both the finite-frequency and ray tomography methods. The Iwaki earthquake and its aftershocks mainly occurred in a boundary zone with strong variations in ...

متن کامل

Nuclear Energy Agency Committee on the Safety of Nuclear Installations

A comprehensive program for the evaluation and enhancement of seismic safety of the Paks Nuclear Power Plant was started in 1993 and now is in progress. In the first two years of the program the urgent and quickly realizable fixes were performed, seismic instrumentation was installed, and a procedure was elaborated for the activities to be performed after a possible earthquake. Re-evaluation of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 20  شماره 

صفحات  -

تاریخ انتشار 2016