Variable-Field Analytical Ultracentrifugation: I. Time-Optimized Sedimentation Equilibrium.

نویسندگان

  • Jia Ma
  • Michael Metrick
  • Rodolfo Ghirlando
  • Huaying Zhao
  • Peter Schuck
چکیده

Sedimentation equilibrium (SE) analytical ultracentrifugation (AUC) is a gold standard for the rigorous determination of macromolecular buoyant molar masses and the thermodynamic study of reversible interactions in solution. A significant experimental drawback is the long time required to attain SE, which is usually on the order of days. We have developed a method for time-optimized SE (toSE) with defined time-varying centrifugal fields that allow SE to be attained in a significantly (up to 10-fold) shorter time than is usually required. To achieve this, numerical Lamm equation solutions for sedimentation in time-varying fields are computed based on initial estimates of macromolecular transport properties. A parameterized rotor-speed schedule is optimized with the goal of achieving a minimal time to equilibrium while limiting transient sample preconcentration at the base of the solution column. The resulting rotor-speed schedule may include multiple over- and underspeeding phases, balancing the formation of gradients from strong sedimentation fluxes with periods of high diffusional transport. The computation is carried out in a new software program called TOSE, which also facilitates convenient experimental implementation. Further, we extend AUC data analysis to sedimentation processes in such time-varying centrifugal fields. Due to the initially high centrifugal fields in toSE and the resulting strong migration, it is possible to extract sedimentation coefficient distributions from the early data. This can provide better estimates of the size of macromolecular complexes and report on sample homogeneity early on, which may be used to further refine the prediction of the rotor-speed schedule. In this manner, the toSE experiment can be adapted in real time to the system under study, maximizing both the information content and the time efficiency of SE experiments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characterization of heterologous protein-protein interactions using analytical ultracentrifugation.

Methods for quantitative characterization of heterologous protein-protein interactions by means of analytical ultracentrifugation (AUC) include sedimentation equilibrium, tracer sedimentation equilibrium, sedimentation velocity, and analytical band sedimentation. Fundamental principles governing the behavior of macromolecules in a centrifugal field are summarized, and the application of these p...

متن کامل

Hydrodynamic Characterization by Analytical Ultracentrifugation and Dynamic Light Scattering

A laboratory-made sample of the polysaccharide xylinan (acetan) has been further characterized with respect to ( i ) purity, (ii) molar mass and polydispersity, and (iii) gross conformation by a combination of hydrodynamic measurements (sedimentation velocity and equilibrium analytical ultracentrifugation, viscometry, and dynamic light scattering) in aqueous NaCl (I = 0.10 mol. L-'). Sedimentat...

متن کامل

Shaptsr 5 Sedimentation equilibrium in the analytical ultracentrifuge

For many years analytical ultracentrifugation was the major source of information on the heterogeneity and molecular size of macromolecules. In the field of protein chemistry the question of solute heterogeneity is now usually addressed by gel electrophoretic and gel chromatographic techniques, and the molecular wetght is either calculated from the amino acid sequence or obtained by mass sPectr...

متن کامل

Analytical ultracentrifugation: sedimentation velocity and sedimentation equilibrium.

Analytical ultracentrifugation (AUC) is a versatile and powerful method for the quantitative analysis of macromolecules in solution. AUC has broad applications for the study of biomacromolecules in a wide range of solvents and over a wide range of solute concentrations. Three optical systems are available for the analytical ultracentrifuge (absorbance, interference, and fluorescence) that permi...

متن کامل

Direct sedimentation analysis of interference optical data in analytical ultracentrifugation.

Sedimentation data acquired with the interference optical scanning system of the Optima XL-I analytical ultracentrifuge can exhibit time-invariant noise components, as well as small radial-invariant baseline offsets, both superimposed onto the radial fringe shift data resulting from the macromolecular solute distribution. A well-established method for the interpretation of such ultracentrifugat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biophysical journal

دوره 109 4  شماره 

صفحات  -

تاریخ انتشار 2015