A method for the morphological analysis of the regurgitant mitral valve using three dimensional echocardiography.
نویسندگان
چکیده
BACKGROUND Atrial en-face reconstructions are commonly used to assess mitral valve morphology in three dimensional (3D) echocardiography but may miss important abnormalities. OBJECTIVE To present a systematic method for the analysis of the regurgitant mitral valve using a combination of en-face and longitudinal views for better anatomical evaluation. METHODS Detailed 3D assessment was done on 58 patients undergoing mitral valve repair. En-face and longitudinal views were compared for detection and location of primary pathology. The quality of acquisitions under general anaesthesia and sedation was also compared. RESULTS Recognition of valve structure was significantly better with longitudinal reconstruction for both mitral leaflets but not for the commissures. Accurate identification of pathology was possible in 95% cases, compared with 50% for en-face reconstruction (p < 0.001). There was no significant difference between imaging under sedation and anaesthesia. CONCLUSION En-face reconstructions alone are inadequate. Additional longitudinal reconstructions are necessary to ensure full inspection of valve morphology.
منابع مشابه
Effect of position on echocardiographic diagnosis of mitral valve prolapse
Echocardiography has been accepted as the diagnostic modality of choice for mitral valve prolapse (MVP). The determine the effect of position on echocardiographic diagnosis of MVP, we examined 693 consecutive patients referred to the echocardiography laboratory because of suspected MVP. First, patients were examined using the usual standard M-Mode echocardiography( left parasternal third or fou...
متن کاملCARDIOVASCULAR MEDICINE A method for the morphological analysis of the regurgitant mitral valve using three dimensional echocardiography
Background: Atrial en-face reconstructions are commonly used to assess mitral valve morphology in three dimensional (3D) echocardiography but may miss important abnormalities. Objective: To present a systematic method for the analysis of the regurgitant mitral valve using a combination of en-face and longitudinal views for better anatomical evaluation. Methods: Detailed 3D assessment was done o...
متن کاملAnalysis of procedural effects of percutaneous edge-to-edge mitral valve repair by 2D and 3D echocardiography.
BACKGROUND Analysis of procedural effects in patients undergoing percutaneous mitral valve repair (PMVR) using the edge-to-edge technique is complex, and common methods to define mitral regurgitation severity based on 2-dimensional (2D) echocardiography are not validated for postprocedural double-orifice mitral valve. This study used 3D transesophageal echocardiography (TEE) to determine the fu...
متن کاملThree-dimensional Doppler. Techniques and clinical applications.
AIMS Colour Doppler is the most widely used technique for assessing valve disease, but eccentric regurgitant jets cannot be visualized and measured by conventional 2D techniques. We have developed a new procedure for three-dimensional (3D) reconstruction of colour Doppler signals. METHODS AND RESULTS Fifty patients with mitral regurgitation underwent transoesophageal echocardiography and 3D a...
متن کاملDetermination of regurgitant fraction in isolated mitral or aortic regurgitation by pulsed Doppler two-dimensional echocardiography.
Measurements of mitral and aortic valve flows were obtained with two-dimensional Doppler echocardiography in 25 patients with isolated mitral (n = 19) or aortic (n = 6) regurgitation and regurgitant fraction was calculated as the difference between the two flows divided by the flow through the regurgitant valve. Results were compared with measurements of regurgitant fraction determined by combi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Heart
دوره 90 7 شماره
صفحات -
تاریخ انتشار 2004