Abstract: Craniofacial Surgical Planning with Augmented Reality: Accuracy of Linear 3D Cephalometric Measurements on 3D Holograms
نویسندگان
چکیده
CONCLUSION: The treatment of migraines requires a multidisciplinary, collaborative approach. The GON can be found approximately 20 mm deep to the skin where it exits the semispinalis muscle, an important consideration when performing targeted injection, diagnostic nerve blocks, and/or migraine surgery. Nerve position may be affected by BMI and gender, which should be considered prior to injection and/or dissection. When performing bilateral interventions, nerve position may differ between sides, particularly with respect to lateral distance from midline. Differences in this study compared to previous cadaver studies may reflect the inclusion of live subjects in prone position compared to cadaver specimens.
منابع مشابه
Development of 3D statistical mandible models for cephalometric measurements
PURPOSE The aim of this study was to provide sex-matched three-dimensional (3D) statistical shape models of the mandible, which would provide cephalometric parameters for 3D treatment planning and cephalometric measurements in orthognathic surgery. MATERIALS AND METHODS The subjects used to create the 3D shape models of the mandible included 23 males and 23 females. The mandibles were segment...
متن کاملLearning Technical Drawing with Augmented Reality and Holograms
Technical drawing is very important for mechanical engineers. The ability to understand and work with technical drawings is a necessary skill for most of them. In general, first year students of mechanical engineering have difficulties in drawing orthographic views and perspectives, since they find it difficult to understand 3D shapes from 2D views. In this paper, we present several tools that ...
متن کاملOverview of Performance and Accuracy of Smartphone Sensors in Augmented Reality Applications
Since incorrect excavations have resulted in extensive and irreparable financial and physical losses, therefore different drillings require having accurate information about the status of the infrastructures. Ubiquitous Geospatial Information System (UBGIS) as a new generation of Geospatial Information System (GIS) can be a good solution to avoid such problems. Augmented Reality (AR) is the ne...
متن کاملComparison of observer reliability of three-dimensional cephalometric landmark identification on subject images from Galileos and i-CAT cone beam CT.
OBJECTIVES Recently, there has been increasing interest in the use of cone beam CT (CBCT) for three-dimensional cephalometric analysis and craniofacial reconstruction in orthodontic and orthognathic surgical treatment planning. However, there is a need to redefine the cephalometric landmarks in three dimensional cephalometric analysis and to demonstrate the reproducibility of landmark identific...
متن کامل3D virtual planning in orthognathic surgery and CAD/CAM surgical splints generation in one patient with craniofacial microsomia: a case report
OBJECTIVE In this case report, the feasibility and precision of tridimensional (3D) virtual planning in one patient with craniofacial microsomia is tested using Nemoceph 3D-OS software (Software Nemotec SL, Madrid, Spain) to predict postoperative outcomes on hard tissue and produce CAD/CAM (Computer Aided Design/Computer Aided Manufacturing) surgical splints. METHODS The clinical protocol con...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 5 شماره
صفحات -
تاریخ انتشار 2017