New method of estimating myocardial infarct size using technetium-99m pyrophosphate and thallium-201 dual single photon emission computed tomography imaging.

نویسندگان

  • Y Maruyama
  • T Kato
  • H Ito
  • S Tanaka
  • N Yoshimoto
  • Y Kishi
  • F Numano
چکیده

A new method was devised to estimate infarct size using dual single photon emission computed tomography with thallium-201 and technetium-99m pyrophosphate. Designating the ratio of infarct area to whole myocardial volume as %MI, the correlation of %MI with other markers of left ventricular dysfunction was examined: peak creatine kinase, ejection fraction and left ventricular asynergy. As %MI correlated well with these markers, it is considered that %MI will be useful for estimating infarct size and predicting the severity of left ventricular dysfunction in the early stage of acute myocardial infarction.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of infarct size and percentage myocardium infarcted in a dog preparation with single photon - emission computed tomography , thallium - 201 , and indium 111 - monoclonal antimyosin

Single photon-emission tomography (SPECT) and indium 1ll-labeled monoclonal antimyosin Fab fragments were used to measure myocardial infarct size in 12 dogs, six subjected to balloon catheter-induced coronary artery occlusion for 6 hr (late reperfusion) and six subjected to occlusion with reperfusion at 2 hr (early reperfusion). Tomographic imaging was performed 24 hr after the intravenous inje...

متن کامل

Measurement of infarct size and percentage myocardium infarcted in a dog preparation with single photon - emission computed tomography , thallium - 201 , and indium 111 - monoclonal

Single photon-emission tomography (SPECT) and indium 1ll-labeled monoclonal antimyosin Fab fragments were used to measure myocardial infarct size in 12 dogs, six subjected to balloon catheter-induced coronary artery occlusion for 6 hr (late reperfusion) and six subjected to occlusion with reperfusion at 2 hr (early reperfusion). Tomographic imaging was performed 24 hr after the intravenous inje...

متن کامل

Lessons from the Tc-99m shortage: implications of substituting Tl-201 for Tc-99m single-photon emission computed tomography.

BACKGROUND In 2009, the Chalk River nuclear reactor closed for repairs that led to a critical shortage of technetium-99m (Tc-99m). Several centers used thallium-201 (Tl-201) as an alternative radiotracer for myocardial perfusion imaging. Because Tl-201 is considered by many as a suboptimal radiotracer, we sought to understand the impact of using Tl-201 (during the Tc-99m shortage) on downstream...

متن کامل

Quantification of myocardial infarct size by thallium - 201 single - photon emission computed tomography : experimental validation in the dog FLORENCE PRIGENT

To evaluate the potential advantages of thallium-201 (201T1) single-photon emission computerized tomography (SPECT) to assess myocardial infarct size in the experimental animal, six normal dogs and 14 dogs with 6 to 8 hr closed-chest coronary occlusion (eight left anterior descending and six left circumflex) were studied. Ten minutes after intravenous administration of 2 mCi of 201T1, 30 projec...

متن کامل

Myocardial damage of the entire ventricular region in a patient with acute myocardial infarction

Technetium-99m-pyrophosphate (99mTc-PYP) has been used, in combination with thallium-201, to estimate the site and extent of myocardial infarcts. We report a case of acute myocardial infarction with severe coronary disease in which the distribution of 99mTc-PYP was extensive. A 78-year-old man presented with dyspnea, and a diagnosis of non-ST-segment elevation acute myocar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Japanese circulation journal

دوره 63 3  شماره 

صفحات  -

تاریخ انتشار 1999