The utility of direct-current as compared to frequency domain measurements in spectrally-constrained diffuse optical tomography toward cancer imaging.
نویسندگان
چکیده
This work investigates, by means of analytical and simulation studies, the performance of spectrally-constrained image reconstruction in Continuous-Wave or Direct-Current (DC) and Frequency Domain (FD) near-infrared optical tomography. A recent analytic approach for estimating the accuracy of target recovery and the level of background artifact for optical tomography at single wavelength, based on the analysis of parametric reconstruction uncertainty level (PRUL), is extended to spectrally-constrained optical tomography. The analytical model is implemented to rank three sets of wavelengths that had been used as spectral prior in an independent experimental study. Subsequent simulation appraises the recovery of oxygenated hemoglobin (HbO), deoxygenated hemoglobin (Hb), water (H2O), scattering amplitude (A), and scattering power (b) using DC-only, DC-excluded FD, and DC-included FD, based on the three sets of wavelengths as the spectral prior. The simulation results support the analytic ranking of the performance of the three sets of spectral priors, and generally agree with the performance outcome of DC-only versus that of DC-excluded FD and DC-included FD. Specifically, this study indicate that: 1) the rank of overall quality of chromophore recovery is Hb, H2O, and HbO from the highest to lowest; and in the scattering part the A is always better recovered than b. This outcome does suggest that the DC-only information gives rise to unique solution to the image reconstruction routine under the given spectral prior. 2) DC-information is not-redundant in FD-reconstruction, as the artifact levels of DC-included FD reconstruction are always lower than those of DC-excluded FD. 3) The artifact level as represented by the noise-to-contrast-ratio is almost always the lowest in DC-only, leading to generally better resolution of multiple targets of identical contrasts over the background than in FD. However, the FD could outperform DC in the recovery of scattering properties including both A and b when the spectral prior is less optimal, implying the benefit of phase-information in scattering recovery in the context of spectrally-constrained optical tomography.
منابع مشابه
Development of Spectrally-Constrained Diffuse Optical Tomography for Imaging Exogenous Contrast Agents
Spectrally-constrained diffuse tomography is used to image endogenous and exogenous tissue chromophore concentrations with higher accuracy than when using individual wavelengths. Reconstructed images from simulated data demonstrate that concentrations of Lutetium Texaphyrin are readily recovered. ©2005 Optical Society of America OCIS codes: (170.3880) Medical and biological imaging; (170.6960) ...
متن کاملMulti-modal molecular diffuse optical tomography system for small animal imaging.
A multi-modal optical imaging system for quantitative 3D bioluminescence and functional diffuse imaging is presented, which has no moving parts and uses mirrors to provide multi-view tomographic data for image reconstruction. It is demonstrated that through the use of trans-illuminated spectral near infrared measurements and spectrally constrained tomographic reconstruction, recovered concentra...
متن کاملSingular value decomposition based regularization prior to spectral mixing improves crosstalk in dynamic imaging using spectral diffuse optical tomography
The spectrally constrained diffuse optical tomography (DOT) method relies on incorporating spectral prior information directly into the image reconstruction algorithm, thereby correlating the underlying optical properties across multiple wavelengths. Although this method has been shown to provide a solution that is stable, the use of conventional Tikhonov-type regularization techniques can lead...
متن کاملDirect-current-based image reconstruction versus direct-current included or excluded frequency-domain reconstruction in diffuse optical tomography.
We study the level of image artifacts in optical tomography associated with measurement uncertainty under three reconstruction configurations, namely, by using only direct-current (DC), DC-excluded frequency-domain, and DC-included frequency-domain data. Analytic and synthetic studies demonstrate that, at the same level of measurement uncertainty typical to optical tomography, the ratio of the ...
متن کاملDevelopment of a multi-wavelength diffuse optical tomography system for early diagnosis of rheumatoid arthritis: simulation, phantoms and healthy human studies
A multi-wavelength diffuse optical tomography (DOT) system has been developed to directly extract physiological information, such as total haemoglobin concentration, from tissue in human hand joints. Novel methods for 3D surface imaging and spectrally constrained image reconstruction are introduced and their potential application to imaging of rheumatoid arthritis is discussed. Results are pres...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Technology in cancer research & treatment
دوره 10 5 شماره
صفحات -