Latarjet Fixation: A Cadaveric Biomechanical Study Evaluating Cortical and Cannulated Screw Fixation.

نویسندگان

  • Hasham M Alvi
  • Emily J Monroe
  • Muturi Muriuki
  • Rajat N Verma
  • Guido Marra
  • Matthew D Saltzman
چکیده

BACKGROUND Attritional bone loss in patients with recurrent anterior instability has successfully been treated with a bone block procedure such as the Latarjet. It has not been previously demonstrated whether cortical or cancellous screws are superior when used for this procedure. PURPOSE To assess the strength of stainless steel cortical screws versus stainless steel cannulated cancellous screws in the Latarjet procedure. STUDY DESIGN Controlled laboratory study. METHODS Ten fresh-frozen matched-pair shoulder specimens were randomized into 2 separate fixation groups: (1) 3.5-mm stainless steel cortical screws and (2) 4.0-mm stainless steel partially threaded cannulated cancellous screws. Shoulder specimens were dissected free of all soft tissue and a 25% glenoid defect was created. The coracoid process was osteomized, placed at the site of the glenoid defect, and fixed in place with 2 parallel screws. RESULTS All 10 specimens failed by screw cutout. Nine of 10 specimens failed by progressive displacement with an increased number of cycles. One specimen in the 4.0-mm screw group failed by catastrophic failure on initiation of the testing protocol. The 3.5-mm screws had a mean of 274 cycles (SD, ±171 cycles; range, 10-443 cycles) to failure. The 4.0-mm screws had a mean of 135 cycles (SD, ±141 cycles; range, 0-284 cycles) to failure. There was no statistically significant difference between the 2 types of screws for cycles required to cause failure (P = .144). CONCLUSION There was no statistically significant difference in energy or cycles to failure when comparing the stainless steel cortical screws versus partially threaded cannulated cancellous screws. CLINICAL RELEVANCE Latarjet may be performed using cortical or cancellous screws without a clear advantage of either option.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical Comparison Between Bashti Bone Plug Technique and Biodegradable Screw for Fixation of Grafts in Ligament surgery

  Background: Ligament reconstruction is a common procedure in orthopedic surgery. Although several popular techniques are currently in use, new methods are proposed for secure fixation of the tendon graft into the bone tunnel. Purposes: We sought to introduce our new technique of Bashti bone plug for fixation of soft tissue graft in anterior cruciate ligament (ACL) reconstruction and to compar...

متن کامل

Biomechanical evaluation of internal fixation techniques for unstable meso-type os acromiale.

BACKGROUND Several internal fixation surgical techniques have been described for the treatment of symptomatic os acromiale. The purpose of this study was to compare the biomechanical characteristics of different internal fixation techniques for the operative treatment of unstable meso-type os acromiale in a cadaveric model. METHODS Testing was performed on 12 matched pairs of cadaveric acromi...

متن کامل

Cannulated screw versus Kirschner-wire fixation for Milch II lateral condyle fractures in a paediatric sawbone model: a biomechanical comparison

Purpose Lateral condyle fractures of the humerus are common in the paediatric population, accounting for up to 20% of elbow fractures. Traditional management involves internal fixation with Kirschner (K)-wires, however, this has been associated with complications and insufficiently rigid fixation. Recently, cannulated screws have been proposed as a more stable method of fixation. While cannulat...

متن کامل

Biomechanical comparison of intramedullary cortical button fixation and interference screw technique for subpectoral biceps tenodesis.

PURPOSE The purpose of this study was to biomechanically evaluate a new technique of intramedullary cortical button fixation for subpectoral biceps tenodesis and to compare it with the interference screw technique. METHODS We compared intramedullary unicortical button fixation (BicepsButton; Arthrex, Naples, FL) with interference screw fixation (Bio-Tenodesis screw; Arthrex) for subpectoral b...

متن کامل

Biomechanical characteristics of fixation methods for floating pubic symphysis

BACKGROUND Floating pubic symphysis (FPS) is a relatively rare injury caused by high-energy mechanisms. There are several fixation methods used to treat FPS, including external fixation, subcutaneous fixation, internal fixation, and percutaneous cannulated screw fixation. To choose the appropriate fixation, it is necessary to study the biomechanical performance of these different methods. The g...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Orthopaedic journal of sports medicine

دوره 4 4  شماره 

صفحات  -

تاریخ انتشار 2016