Nonfluoroscopic catheter navigation for radiofrequency catheter ablation of supraventricular tachycardia in children.

نویسندگان

  • John Papagiannis
  • Alexandros Tsoutsinos
  • George Kirvassilis
  • Ioanna Sofianidou
  • Theofili Koussi
  • Cleo Laskari
  • Maria Kiaffas
  • Sotiria Apostolopoulou
  • Spyridon Rammos
چکیده

BACKGROUND Radiofrequency catheter ablation (RCA) of supraventricular tachycardia (SVT) in children is highly successful but requires exposure to radiation. Nonfluoroscopic mapping systems may significantly reduce fluoroscopy time. METHODS Forty consecutive pediatric patients who underwent RCA for accessory pathways (AP) or AV nodal reentrant tachycardia (AVNRT) with use of a nonfluoroscopic navigation system (Ensite NavX) (group A) were compared retrospectively to 40 consecutive patients with similar diagnoses who underwent RCA with fluoroscopic guidance only (group B). RESULTS Group A (mean age 12.1+/-2.9 years, mean weight 47+/-13.9 kg) consisted of 11 patients (27.7%) with AVNRT and 29 (72.5%) with AP. Group B (mean age 10.9+/-3.1 years, mean weight 47.1+/-17.1 kg) consisted of 7 patients (17.5%) with AVNRT and 33 (82.5%) with AP. There were no significant differences in AP location, patients with congenital heart disease, and number of radiofrequency lesions. Fluoroscopy time was significantly shorter in group A than in group B (10.4+/-6.1, range 3.1-28.8 minutes, vs 24.9+/-16.0, range 4.4-82.0 minutes, P<0.0001). Procedure duration was also significantly shorter in group A than in group B (170+/-68.5, range 90-420 minutes, vs 218+/-69.3, range 90-360 minutes, P<0.0001). Initial success was 95% in group A and 100% in group B. Tachycardia recurrences occurred in two patients in group A (5%) and six patients in group B (15%). Final success, including repeat ablations for recurrences or failures, was 100% in both groups. CONCLUSIONS The use of a nonfluoroscopic system for catheter navigation significantly reduced fluoroscopy exposure and total procedure duration of RCA of common SVT substrates in children.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A nonfluoroscopic approach for electrophysiology and catheter ablation procedures using a three-dimensional navigation system.

BACKGROUND Three-dimensional (3D) electroanatomical navigation systems decrease the fluoroscopy time of electrophysiology and ablation procedures. The aim of this study was to assess the safety and efficacy of a complete nonfluoroscopic approach for electrophysiologic studies and right-sided catheter ablations for supraventricular tachycardia in patients with normal cardiac anatomy using a 3D, ...

متن کامل

Radiofrequency Catheter Ablation in Children with Supraventricular Tachycardias: Intermediate Term Follow Up Results

THE PURPOSE OF THE STUDY Radiofrequency (RF) catheter ablation represents an important advance in the management of children with cardiac arrhythmias and has rapidly become the standard and effective line of therapy for supraventricular tachycardias (SVTs) in pediatrics. The purpose of this study was to evaluate the intermediate term follow up results of radiofrequency catheter ablation in trea...

متن کامل

Percutaneous radiofrequency catheter ablation for supraventricular arrhythmias in children.

Nineteen procedures were performed in 17 children, aged 10 months to 17 years, using catheter radiofrequency applications for the management of malignant or drug-resistant supraventricular tachyarrhythmias. Diagnoses were junctional ectopic tachycardia in 1 patient, atrioventricular (AV) node reentrant tachycardia in 4 and accessory pathway-mediated tachycardia in 12. Accessory pathway location...

متن کامل

NASPE 25TH ANNIVERSARY SERIES Catheter Ablation of Supraventricular Arrhythmias: State of the Art

The era of catheter ablation for the treatment of arrhythmias began in 1981, when Dr. Melvin Scheinman performed the first atrioventricular junction ablation using direct-current shocks in a patient with drug-refractory atrial fibrillation and an uncontrolled ventricular rate.1 Because of the barotrauma associated with intracardiac high-energy shocks, direct-current catheter ablation played onl...

متن کامل

Catheter ablation of supraventricular arrhythmias: state of the art.

The era of catheter ablation for the treatment of arrhythmias began in 1981 when Dr. Melvin Scheinman performed the first atrioventricular junction ablation using direct current shocks in a patient with drug refractory atrial fibrillation and an uncontrolled ventricular rate.1 Because of the barotrauma associated with intracardiac, high energy shocks, direct current catheter ablation played onl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Pacing and clinical electrophysiology : PACE

دوره 29 9  شماره 

صفحات  -

تاریخ انتشار 2006