Determination of sulfur and selected trace elements in metallothionein-like proteins using capillary electrophoresis hyphenated to inductively coupled plasma mass spectrometry with an octopole reaction cell.

نویسندگان

  • Daniel Pröfrock
  • Peter Leonhard
  • Andreas Prange
چکیده

The determination of sulfur in biologically relevant samples such as metalloproteins is described. The analytical methodology used is based on robust on-line coupling between capillary electrophoresis (CE) and octopole reaction cell inductively-coupled plasma mass spectrometry (ORC-ICP-MS). Polyatomic ions that form in the plasma and interfere with the determination of S at mass 32 are minimised by addition of xenon to the collision cell. The method has been applied to the separation and simultaneous element-specific detection of sulfur, cadmium, copper, and zinc in commercially available metallothionein preparations (MT) and metallothionein-like proteins (MLP) extracted from liver samples of bream ( Abramis brama L.) caught in the river Elbe, Germany. Instrumental detection limits have been calculated according to the German standard procedure DIN 32645 for the determination of sulfur and some simultaneously measured trace elements in aqueous solution. For sulfur detection limits down to 1.3 microg L(-1) ((34)S) and 3.2 microg L(-1) ((32)S) were derived. For the other trace elements determined simultaneously detection limits ranging from 300 ng L(-1) ((58)Ni) to 500 ng L(-1) ((66)Zn, (55)Mn) were achieved. For quantification of sulfur and cadmium in a commercially available MT preparation under hyphenated conditions the use of external calibration is suggested. Finally, the need for proper sample-preparation technique will be discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Identification of a metallothionein in Synechococcus by capillary electrophoresis hyphenated with inductively coupled plasma mass spectrometry.

A home-made system hyphenating capillary electrophoresis with an inductively coupled plasma mass spectrometer (CE-ICP-MS) for cadmium speciation of protein-binding and free cadmium ions in solution is presented. The CE-ICP-MS interface consisted of an acrylic block with an internal volume ca. 20 microL in which a platinum electrode, a capillary column, and a connection to an ICP nebulizer were ...

متن کامل

Rapid and Reliable Routine Analysis of Urine by Octopole Reaction Cell ICP-MS Application

The Agilent 7500c Inductively Coupled Plasma Mass Spectrometer (ICP-MS) was used for the fast, routine, and reliable analysis of 23 trace elements in urine. The complete method validation for all elements is described, including the evaluation of short-term and long-term stability, the analysis of different reference materials and the discussion of precision and accuracy in internal and externa...

متن کامل

Determination of traces of radionuclides by hyphenated techniques coupled to inductively coupled plasma mass spectrometry (ICP-MS) Determinació de traces de radionúclids emprant tècniques acoblades a l’espectrometria de masses i plasma induït per alta freqüència (ICP-MS)

An overview is given of the current state of the art for the determination of radionuclide traces in the environment and the separation of fission products and actinides in nuclear samples by techniques like flow-injection (FI)/sequential injection analysis (SIA) and chromatography hyphenated to inductively coupled plasma mass spectrometry (ICP-MS).

متن کامل

Rapid and Reliable Routine Analysis of Urine by Octopole Reaction Cell ICP-MS Application

The Agilent 7500c Inductively Coupled Plasma Mass Spectrometer (ICP-MS) was used for the fast, routine, and reliable analysis of 23 trace elements in urine. The complete method validation for all elements is described, including the evaluation of short-term and long-term stability, the analysis of different reference materials and the discussion of precision and accuracy in internal and externa...

متن کامل

Trace metal speciation by capillary electrophoresis hyphenated to inductively coupled plasma mass spectrometry: sulfate and chloride complexes of Np(V) and Pu(V).

In the framework of nuclear waste disposal, it is very important to well understand the behavior of actinides in the presence of the common environmental inorganic ligands such as sulfate and chloride. In this work, the AnO2SO4(-) and AnO2Cl 1-1 complexes have been evidenced by capillary electrophoresis-inductively coupled plasma mass spectrometry (CE-ICPMS) in perchlorate/chloride and in perch...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical and bioanalytical chemistry

دوره 377 1  شماره 

صفحات  -

تاریخ انتشار 2003