Automatic individual calibration in fall detection--an integrative ambulatory measurement framework.
نویسندگان
چکیده
The objective of the current study was to demonstrate the utility of a new integrative ambulatory measurement (IAM) framework by developing and evaluating an individual calibration function in fall detection application. Ten healthy elderly persons were involved in a laboratory study and tested in a protocol comprising various types of activities of daily living and slip-induced backward falls. Inertial measurement units attached to the trunk and thigh segments were used to measure trunk angular kinematics and thigh accelerations. The effect of individual calibration was evaluated with previously developed fall detection algorithm. The results indicated that with individual calibration, the fall detection performance achieved approximately the same level of sensitivity (100% vs. 100%) and specificity (95.25% vs. 95.65%); however, response time was significantly lower than without (249 ms vs. 255 ms). It was concluded that the automatic individual calibration using the IAM framework improves the performance of fall detection, which has a greater implication in preventing/minimising injuries associated with fall accidents.
منابع مشابه
Estimation and Calibration of Robot Link Parameters with Intelligent Techniques
Abstract: Using robot manipulators for high accuracy applications require precise value of the kinematics parameters. Since measurement of kinematics parameters are usually associated with errors and accurate measurement of them is an expensive task, automatic calibration of robot link parameters makes the task of kinematics parameters determination much easier. In this paper a simple and easy ...
متن کامل A novel approach to automatic position calibration for pixelated crystals in gamma imaging
Introduction: The position estimation in gamma detection system will have constant misplacements which can be corrected in the calibration procedure. In the pixelated crystal uniformly irradiation of detector will produce irregular shape due to position estimation errors. This image is called flood field image and is used to calibrate the position estimation. In this work we pr...
متن کاملDetecting falls with 3D range camera in ambient assisted living applications: a preliminary study.
In recent years several world-wide ambient assisted living (AAL) programs have been activated in order to improve the quality of life of older people, and to strengthen the industrial base through the use of information and communication technologies. An important issue is extending the time that older people can live in their home environment, by increasing their autonomy and helping them to c...
متن کاملA Unified Framework for Delineation of Ambulatory Holter ECG Events via Analysis of a Multiple-Order Derivative Wavelet-Based Measure
In this study, a new long-duration holter electrocardiogram (ECG) major events detection-delineation algorithm is described which operates based on the false-alarm error bounded segmentation of a decision statistic with simple mathematical origin. To meet this end, first three-lead holter data is pre-processed by implementation of an appropriate bandpass finite-duration impulse response (FIR) f...
متن کاملA New Approach to Self-Localization for Mobile Robots Using Sensor Data Fusion
This paper proposes a new approach for calibration of dead reckoning process. Using the well-known UMBmark (University of Michigan Benchmark) is not sufficient for a desirable calibration of dead reckoning. Besides, existing calibration methods usually require explicit measurement of actual motion of the robot. Some recent methods use the smart encoder trailer or long range finder sensors such ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Computer methods in biomechanics and biomedical engineering
دوره 16 5 شماره
صفحات -
تاریخ انتشار 2013