Wire-guided catheter exchange after failed direct laryngoscopy in critically ill adults.
نویسندگان
چکیده
STUDY OBJECTIVE To describe a technique for tracheal intubation after failed direct laryngoscopy using a Laryngeal Mask Airway (LMA) to secure the airway and to establish ventilation, and as a conduit for fiberoptic intubation utilizing a pre-packaged, convenient, and commercially available wire-guided catheter exchange kit. DESIGN Retrospective case series. SETTING University hospital. MEASUREMENTS The cases of 5 critically ill adult patients who required intubation for respiratory failure, and in whom direct laryngoscopy was unsuccessful and unanticipated, were reviewed. Difficult intubation was defined as > or = two attempts by direct laryngoscopy and use of an airway adjunct/alternate airway device, or > or = three attempts by direct laryngoscopy. Occurrence of hypotension, hypoxemia, and the time required to accomplish the intubation were recorded. MAIN RESULTS Patients' tracheas were intubated in the emergency department (n = 2), the intensive care unit (n = 2), and the radiology department (n = 1). An Eschmann endotracheal tube (ETT) introducer was used in 4 of the 5 patients, and a GlideScope was used in the fifth patient. After failed direct laryngoscopy, an LMA Classic was inserted to gain an airway, after which a fiberoptic bronchoscope and wire-guided catheter exchange set was used to change the LMA to a conventional ETT. Ventilation was maintained via the LMA with an attached bronchoscope adapter throughout the procedure. CONCLUSIONS In all 5 patients, the trachea was successfully intubated within three minutes on the first attempt, using a wire-guided exchange, without hypoxemia or hypotension.
منابع مشابه
Randomized Trial of Video Laryngoscopy for Endotracheal Intubation of Critically Ill Adults.
OBJECTIVE To evaluate the effect of video laryngoscopy on the rate of endotracheal intubation on first laryngoscopy attempt among critically ill adults. DESIGN A randomized, parallel-group, pragmatic trial of video compared with direct laryngoscopy for 150 adults undergoing endotracheal intubation by Pulmonary and Critical Care Medicine fellows. SETTING Medical ICU in a tertiary, academic m...
متن کاملComparison of early versus late use of antibiotic locks in the treatment of catheter-related bacteremia.
BACKGROUND AND OBJECTIVES This retrospective study compared the effectiveness of the timing of the antibiotic locks to clear catheter-related bacteremia in children on chronic hemodialysis. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS The early antibiotic lock group received antibiotic locks along with systemic antibiotics from the very beginning of catheter-related bacteremia. The late anti...
متن کاملNovel use of an exchange catheter to facilitate intubation with an Aintree catheter in a tall patient with a predicted difficult airway: a case report
INTRODUCTION The Aintree intubating catheter (Cook® Medical Inc., Bloomington, IN, USA) has been shown to successfully facilitate difficult intubations when other methods have failed. The Aintree intubating catheter (Cook® Medical Inc., Bloomington, IN, USA) has a fixed length of 56 cm, and it has been suggested in the literature that it may be too short for safe use in patients who are tall. ...
متن کاملARTIGO ORIGINAL Summary Objectives: Evaluate the safety and effectiveness of a training program for performing ultrasound-guided internal jugular vein cannulation in critically ill patients. Methods: Cohort prospective study, evaluating adult patients admitted in a teaching intensive care
Objectives: Evaluate the safety and effectiveness of a training program for performing ultrasound-guided internal jugular vein cannulation in critically ill patients. Methods: Cohort prospective study, evaluating adult patients admitted in a teaching intensive care unit (ICU). Catheter placement was performed by an ICU medical resident. The patient’s baseline characteristics, vessel’s position ...
متن کاملDialysis catheter fibrin sheath stripping: a useful technique after failed catheter exchange
Fibrin sheath formation around long-term haemodialysis catheter is a common cause of failed dialysis access. Treatment options include pharmacological and mechanical methods. This paper reports a case of failed dialysis access due to fibrin sheath encasement. Pharmacologic thrombolysis, mechanical disruption using guide wire and catheter exchange had failed to address the issue. Eventually, fib...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of clinical anesthesia
دوره 22 2 شماره
صفحات -
تاریخ انتشار 2010