An internal normalization technique for unmixing total-spiked mixtures with application to MC-ICP-MS
نویسندگان
چکیده
Isotopic analyses of a total-spiked sample by multiple-collector inductively coupled plasma mass spectrometry (MCICP-MS) are often corrected for mass fractionation by doping the sample with an external tracer element of known isotopic composition and similar mass. However, because of the potential for elemental fractionation on the ICP-MS, internal normalization methods should be used whenever possible. Here, we present a weighted non-linear inversion of the mass spectra of a total-spiked sample, using linear, power, and exponential laws. This method was applied to the calibration of an Osmium tracer solution enriched in Os, and the results agree with iterative unmixing algorithms. # 2001 Elsevier Science Ltd. All rights reserved.
منابع مشابه
Comparison of two ELISA-based methods for the detection of microcystins in blood serum.
Microcystins (MCs) are cyanobacterial toxins which place the public at risk via exposure to MC contaminated water, food or algal food supplements. Subsequent to the fatal intravenous exposure of dialysis patients in Caruaru, Brazil, several techniques (LC-MS, GC-MS and ELISA) were adapted to detect MCs in human serum. As patients chronically exposed to low concentrations of MCs also present wit...
متن کاملEvaluation strategies and uncertainty calculation of isotope amount ratios measured by MC ICP-MS on the example of Sr
This paper critically reviews the state-of-the-art of isotope amount ratio measurements by solution-based multi-collector inductively coupled plasma mass spectrometry (MC ICP-MS) and presents guidelines for corresponding data reduction strategies and uncertainty assessments based on the example of n((87)Sr)/n((86)Sr) isotope ratios. This ratio shows variation attributable to natural radiogenic ...
متن کاملThe performance of single and multi-collector ICP-MS instruments for fast and reliable 34S/32S isotope ratio measurements†
The performance and validation characteristics of different single collector inductively coupled plasma mass spectrometers based on different technical principles (ICP-SFMS, ICP-QMS in reaction and collision modes, and ICP-MS/MS) were evaluated in comparison to the performance of MC ICP-MS for fast and reliable S isotope ratio measurements. The validation included the determination of LOD, BEC,...
متن کاملSelf-aliquoting micro-grooves in combination with laser ablation-ICP-mass spectrometry for the analysis of challenging liquids: quantification of lead in whole blood
We present a technique for the fast screening of the lead concentration in whole blood samples using laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS). The whole blood sample is deposited on a polymeric surface and wiped across a set of micro-grooves previously engraved into the surface. The engraving of the micro-grooves was accomplished with the same laser system used fo...
متن کاملDetermination of Chromium, Selenium, and Molybdenum in Nutritional Products by ICP-MS Authors
An ICP-MS validated method for the rapid determination of chromium (Cr), selenium (Se), and molybdenum (Mo) in infant formula and adult nutritional products was successfully transferred from the Agilent 7500cx ICP-MS to the Agilent 7700x ICP-MS, and from lab 1 to lab 2, respectively. The key advantage of the method is that all samples can be analyzed using a single-cell gas mode (helium mode) t...