Variations in Case-Mix-Adjusted Duration of Mechanical Ventilation Among ICUs.

نویسندگان

  • Andrew A Kramer
  • Hayley B Gershengorn
  • Hannah Wunsch
  • Jack E Zimmerman
چکیده

OBJECTIVES To develop a model that predicts the duration of mechanical ventilation and then to use this model to compare observed versus expected duration of mechanical ventilation across ICUs. DESIGN Retrospective cohort analysis. SETTING Eighty-six eligible ICUs at 48 U.S. hospitals. PATIENTS ICU patients receiving mechanical ventilation on day 1 (n = 56,336) admitted from January 2013 to September 2014. INTERVENTIONS None. MEASUREMENTS AND MAIN RESULTS We developed and validated a multivariable logistic regression model for predicting duration of mechanical ventilation using ICU day 1 patient characteristics. Mean observed minus expected duration of mechanical ventilation was then obtained across patients and for each ICU. The accuracy of the model was assessed using R. We defined better performing units as ICUs that had an observed minus expected duration of mechanical ventilation less than -0.5 days and a p value of less than 0.01; and poorer performing units as ICUs with an observed minus expected duration of mechanical ventilation greater than +0.5 days and a p value of less than 0.01. The factors accounting for the majority of the model's explanatory power were diagnosis (71%) and physiologic abnormalities (24%). For individual patients, the difference between observed and mean predicted duration of mechanical ventilation was 3.3 hours (95% CI, 2.8-3.9) with R equal to 21.6%. The mean observed minus expected duration of mechanical ventilation across ICUs was 3.8 hours (95% CI, 2.1-5.5), with R equal to 69.9%. Among the 86 ICUs, 66 (76.7%) had an observed mean mechanical ventilation duration that was within 0.5 days of predicted. Five ICUs had significantly (p < 0.01) poorer performance (observed minus expected duration of mechanical ventilation, > 0.5 d) and 14 ICUs significantly (p < 0.01) better performance (observed minus expected duration of mechanical ventilation, < -0.5 d). CONCLUSIONS Comparison of observed and case-mix-adjusted predicted duration of mechanical ventilation can accurately assess and compare duration of mechanical ventilation across ICUs, but cannot accurately predict an individual patient's mechanical ventilation duration. There are substantial differences in duration of mechanical ventilation across ICU and their association with unit practices and processes of care warrants examination.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Review Paper: The Bed Incline and Prevention of Ventilator-Associated Pneumonia

Background: Ventilator-Associated Pneumonia (VAP) is the most common nosocomial (hospital acquired) infection among patients undergoing mechanical ventilation. It increases mortality rate, duration of mechanical intubated ventilation, and hospitalization in the Intensive Care Units (ICUs). This review study aims to determine the proper gradient of a hospital bed in preventing VAP in patients ho...

متن کامل

بررسی تاثیر پروتکل جداسازی بیمار بر طول مدت تهویه مکانیکی

  Abstract   Background and Aim: While in many instances, mechanical ventilation discontinuation is assessed subjectively by a number of parameters protocols would provide safe and effective discontinuation. This study aimed to determine the effect of discontinuation protocol on the duration of mechanical ventilation among patients hospitalized in intensive care units (ICUs) of Al Zahra hospita...

متن کامل

Mechanical ventilation and clinical practice heterogeneity in intensive care units: a multicenter case-vignette study

BACKGROUND Observational studies on mechanical ventilation (MV) show practice variations across ICUs. We sought to determine, with a case-vignette study, the heterogeneity of processes of care in ICUs focusing on mechanical ventilation procedures, and whether organizational patterns or physician characteristics influence practice variations. METHODS We conducted a cross-sectional multicenter ...

متن کامل

Influencing Factors on COVID-19 Infection Despite Protective Measures Among Orthopedic Residents: Air Ventilation and Contact Duration

Despite all protective measures, the number of contacts and cumulative contact duration in the frontline screening seem to be the influencing factors. Three out 5 of our first year orthopedic residents showed symptoms of the disease 2-3 weeks after starting their tasks in the COVID-19 floor. Other residents that were only visiting patients in the COVID floor did not become symptomatic which als...

متن کامل

Characteristics and outcome for admissions to adult, general critical care units with acute severe asthma: a secondary analysis of the ICNARC Case Mix Programme Database

INTRODUCTION This report describes the case mix, outcome and activity (duration of intensive care unit [ICU] and hospital stay, inter-hospital transfer, and readmissions to the ICU) for admissions to ICUs for acute severe asthma, and investigates the effect of case mix factors on outcome. METHODS We conducted a secondary analysis of data from a high-quality clinical database (the Intensive Ca...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Critical care medicine

دوره 44 6  شماره 

صفحات  -

تاریخ انتشار 2016