Effect of different cleansers on the weight and ion release of removable partial denture: an in vitro study

نویسندگان

  • Daniela N.B. FELIPUCCI
  • Letícia R. DAVI
  • Helena F.O. PARANHOS
  • Osvaldo L. BEZZON
  • Rodrigo F. SILVA
  • Fernando BARBOSA JUNIOR
  • Valéria O. PAGNANO
چکیده

OBJECTIVE Removable partial dentures (RPD) require different hygiene care, and association of brushing and chemical cleansing is the most recommended to control biofilm formation. However, the effect of cleansers has not been evaluated in RPD metallic components. The aim of this study was to evaluate in vitro the effect of different denture cleansers on the weight and ion release of RPD. MATERIAL AND METHODS Five specimens (12x3 mm metallic disc positioned in a 38x18x4 mm mould filled with resin), 7 cleanser agents [Periogard (PE), Cepacol (CE), Corega Tabs (CT), Medical Interporous (MI), Polident (PO), 0.05% sodium hypochlorite (NaOCl), and distilled water (DW) (control)] and 2 cobalt-chromium alloys [DeguDent (DD), and VeraPDI (VPDI)] were used for each experimental situation. One hundred and eighty immersions were performed and the weight was analyzed with a high precision analytic balance. Data were recorded before and after the immersions. The ion release was analyzed using mass spectrometry with inductively coupled plasma. Data were analyzed by two-way ANOVA and Tukey HSD post hoc test at 5% significance level. RESULTS Statistical analysis showed that CT and MI had higher values of weight loss with higher change in VPDI alloy compared to DD. The solutions that caused more ion release were NaOCl and MI. CONCLUSIONS It may be concluded that 0.05% NaOCl and Medical Interporous tablets are not suitable as auxiliary chemical solutions for RPD care.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stress Distribution in Natural Tooth and Implant Supported Removable Partial Denture with Different Attachment Types: A Photoelastic Analysis

Background and Aim: Different attachment designs have been developed to connect implant to natural teeth in partial dentures; however, adequate studies have not been performed to determine stress distribution patterns in these designs. The present study aimed to assess stress distribution patterns in natural tooth and implant supported removable partial denture with different attachment designs...

متن کامل

Evaluation of the Effect of Household Cleansers on the Color Change of Two Types of Permanent Soft Liners: An In Vitro Study

Many patients use household cleaners to clean denture which can cause discoloration and damage soft liners. The purpose of this study was to evaluate the effect of household cleansers on the color change of two types of permanent soft liners. Methods: In this interventional study, 80 permanent silicone soft liners, including 40 heat-cured liners (Molloplast-B, Detax Gmbh & Co. ...

متن کامل

Efficacy of denture cleansers in reducing microbial counts from removable partial dentures: a short-term clinical evaluation.

This clinical study investigated if daily immersion in denture cleansers reduces microbial counts on removable partial denture's (RPD) biofilm. Twenty-five RPD wearer volunteers were selected and instructed to complement the hygiene of their dentures by immersing them in an enzymatic peroxide-based denture cleanser (Polident® 3 minute) once a day for 3 min for a period of 15 days. The biofilm w...

متن کامل

Effect of denture cleansers on metal ion release and surface roughness of denture base materials.

Chemical disinfectants are usually associated with mechanical methods to remove stains and reduce biofilm formation. This study evaluated the effect of disinfectants on release of metal ions and surface roughness of commercially pure titanium, metal alloys, and heat-polymerized acrylic resin, simulating 180 immersion trials. Disk-shaped specimens were fabricated with commercially pure titanium ...

متن کامل

Case Report: Implant-Supported Removable Partial Denture In A Mandibular Kennedy CL II: A Clinical Report

Abstract The implant-supported removable partial dentures should be an alternative to conventional removable partial dentures and implant-supported fixed partial prostheses when the implant’s insertion is confined by bone height and thickness. Placing a single implant in the posterior region would modify the Kennedy Class II configuration to a Kennedy Class III and increase the stability a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 19  شماره 

صفحات  -

تاریخ انتشار 2011