The accuracy of implant impressions: a systematic review.
نویسندگان
چکیده
STATEMENT OF PROBLEM Various implant impression techniques, such as the splint, pick-up, and transfer techniques, have been introduced, and some techniques may be more accurate than others. Also, clinically, some factors, including the angulation or depth of implants, may affect the accuracy of the implant impressions. PURPOSE The purposes of this review were to: (1) investigate the accuracy of published implant impression techniques, and (2) examine the clinical factors affecting implant impression accuracy. MATERIAL AND METHODS An electronic search was performed in June 2008 of MEDLINE, EMBASE, and Cochrane Library databases with the key words implant, implants, impression, and impressions. To be included, the study had to investigate the accuracy of implant impressions and be published in an English peer-reviewed journal. In addition, a hand search was performed to enrich the results for the time period from January 1980 to May 2008. After executing the search strategies, 41 articles were selected to be included in the review process. RESULTS All of the selected articles were in vitro studies. Of the 17 studies that compared the accuracy between the splint and nonsplint techniques, 7 advocated the splint technique, 3 advocated the nonsplint technique, and 7 reported no difference. Fourteen studies compared the accuracy of pick-up and transfer impression techniques, and 5 showed more accurate impression with the pick-up techniques, 2 with the transfer technique, and 7 showed no difference. The number of implants affected the comparison of the pick-up and splint techniques. Eleven studies compared the accuracy of polyether and vinyl polysiloxane (VPS), and 10 of 11 reported no difference between the 2 materials. Four studies examined the effect of implant angulation on the accuracy of impressions. Two studies reported higher accuracy with straight implants, while the other 2 reported there was no angulation effect. CONCLUSIONS The review of abutment level or implant level internal connection implants indicated that more studies reported greater accuracy with the splint technique than with the nonsplint technique. For situations in which there were 3 or fewer implants, most studies showed no difference between the pick-up and transfer techniques, whereas for 4 or more implants, more studies showed higher accuracy with the pick-up technique. Polyether and VPS were the recommended materials for the implant impressions.
منابع مشابه
تعیین دقت ثبت ایمپلنت و جزئیات سطحی با استفاده از پلیاتر و پلیوینیل سایلوکسان با روش تری بسته
Background and Aims: Making accurate impressions of prepared teeth when they are adjacent to dental implants is of great importance. In these situations, disregarding the selection of appropriate impression material and technique, not only can affect accuracy of transferring of the 3-dimentional spatial status of implant, but also can jeopardize the accurate recording of tooth. In the present...
متن کاملEffects of Water/Powder Ratio of Irreversible Hydrocolloid on Dimensional Stability of Impressions
Background and Aim: Water/powder ratio is effective on some properties of irreversible hydrocolloid impression materials. This study aimed to determine the ef-fects of water/powder ratio of irreversible hydrocolloid impression materials on di-mensional stability of impressions. Materials and Methods: In this in vitro experimental study, a metal model with two abutments as anchoring support for...
متن کاملمقایسه دقت تکنیکهای مختلف قالبگیری در قالبهای سطح اباتمنت در ایمپلنتهای دندانی با طرح All-on-4
Background and Aims: Passive fit of prosthetic frameworks is a major concern in implant dentistry. Impression technique is one of the several variables that may affect the outcome of dental implants. The purpose of this study was to compare the three dimensional accuracy of direct and indirect abutment level implant impressions of ALL-ON-4 treatment plan.Materials and Methods: A reference acryl...
متن کاملInternal vs. external connections for abutments/reconstructions: a systematic review.
OBJECTIVES The objectives of the review were (1) to evaluate the accuracy of implant-level impressions in cases with internal and external connection abutments/reconstructions, and (2) to evaluate the incidence of technical complications of internal and external connection metal- or zirconia-based abutments and single-implant reconstructions. MATERIALS AND METHODS A MEDLINE electronic search ...
متن کاملDimensional Accuracy of Polyvinyl Siloxane Impression Materials Considering Impression Techniques– A Literature Review
Objectives Impression accuracy is the main determinant of the fit, form and function of prosthetic restorations. Polyvinyl siloxane (PVS) is the material of choice in most clinical situations. The purpose of this paper is to provide an up-to-date review of scientific articles which discuss the dimensional accuracy of PVS impression material using various impression techniques, tray types and sp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of prosthetic dentistry
دوره 100 4 شماره
صفحات -
تاریخ انتشار 2008