Computer usage and task-switching during resident’s working day: Disruptive or not?

نویسندگان

  • Marie Méan
  • Antoine Garnier
  • Nathalie Wenger
  • Julien Castioni
  • Gérard Waeber
  • Pedro Marques-Vidal
چکیده

BACKGROUND Recent implementation of electronic health records (EHR) has dramatically changed medical ward organization. While residents in general internal medicine use EHR systems half of their working time, whether computer usage impacts residents' workflow remains uncertain. We aimed to observe the frequency of task-switches occurring during resident's work and to assess whether computer usage was associated with task-switching. METHODS In a large Swiss academic university hospital, we conducted, between May 26 and July 24, 2015 a time-motion study to assess how residents in general internal medicine organize their working day. RESULTS We observed 49 day and 17 evening shifts of 36 residents, amounting to 697 working hours. During day shifts, residents spent 5.4 hours using a computer (mean total working time: 11.6 hours per day). On average, residents switched 15 times per hour from a task to another. Task-switching peaked between 8:00-9:00 and 16:00-17:00. Task-switching was not associated with resident's characteristics and no association was found between task-switching and extra hours (Spearman r = 0.220, p = 0.137 for day and r = 0.483, p = 0.058 for evening shifts). Computer usage occurred more frequently at the beginning or ends of day shifts and was associated with decreased overall task-switching. CONCLUSION Task-switching occurs very frequently during resident's working day. Despite the fact that residents used a computer half of their working time, computer usage was associated with decreased task-switching. Whether frequent task-switches and computer usage impact the quality of patient care and resident's work must be evaluated in further studies.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sensitivity Assessment of Lightning Protection Device Aging Effect on Distribution Substation Insulation

 Insufficient electrical endurance of equipment and insulation failure against overvoltage is one of the most effective reasons for failure the power line. Lightening, switching or other disruptive parameters can cause line outage or distribution substation failure. There are different devices used to improve the safety, reliability, and power quality of the system. Surge arresters are one of t...

متن کامل

The role of dominance and subordination in the disruptive behaviors of nurses working at military hospitals: a qualitative content analysis

Background and aims: The existence of disruptive behaviors in medical centers is a long term problem that has very negative consequences for nurses, organizations, and patients. Since the disruptive behaviors are a complex, multi-dimensional, interactive, and social phenomenon, and they are depended on the culture and religion of each community; therefore, this study aimed to explore percep...

متن کامل

Switching to Real-Time Tasks in Multi-Tasking Dialogue

In this paper we describe an empirical study of human-human multi-tasking dialogues (MTD), where people perform multiple verbal tasks overlapped in time. We examined how conversants switch from the ongoing task to a real-time task. We found that 1) conversants use discourse markers and prosodic cues to signal task switching, similar to how they signal topic shifts in single-tasking speech; 2) c...

متن کامل

بررسی شکایات چشمی و عوامل مرتبط در کاربران رایانه

Abstract Background: It is nearly twenty years passed from introducing of computer to human life and it is now an inseparable part of our life, because of widespread use of computer, many studies have been done for finding safety and health principle for these users, the aim of this study is determination of ophthalmic complains in Shahid Sadoughi University computer users. Methods: This des...

متن کامل

Estimation of New Weighted Controlled Switching Overvoltage by RBFN Model

Mitigating switching overvoltages (SOVs) and conducting well-suited insulation coordination for handling stresses are very important in UHV transmission Lines. The best strategy in the absence of arresters is controlled switching (CS). Although elaborate works on electromagnetic transients are considered in the process of designing transmission systems, such works are not prevalent in day-to-da...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017