Feasibility of subendocardial and subepicardial myocardial perfusion measurements in healthy normals with 15O-labeled water and positron emission tomography

نویسندگان

  • Ilse A. Vermeltfoort
  • Pieter G. Raijmakers
  • Mark Lubberink
  • Tjeerd Germans
  • Albert C. van Rossum
  • Adriaan A. Lammertsma
  • Paul Knaapen
چکیده

BACKGROUND Positron emission tomography (PET) enables robust and reproducible measurements of myocardial blood flow (MBF). However, the relatively limited resolution of PET till recently prohibited distinction between the subendocardial and the subepicardial layers in non-hypertrophied myocardium. Recent developments in hard- and software, however, have enabled to identify a transmural gradient difference in animal experiments. The aim of this study is to determine the feasibility of subendocardial and subepicardial MBF in normal human hearts assessed with (15)O-labeled water PET. METHODS Twenty-seven healthy subjects (mean age 41 ± 13 years; 11 men) were studied with (15)O-labeled water PET to quantify resting and hyperaemic (adenosine) MBF at a subendocardial and subepicardial level. In addition, cardiac magnetic resonance imaging was performed to determine left ventricular (LV) volumes and function. RESULTS Mean rest MBF was 1.46 ± 0.49 in the subendocardium, and 1.14 ± 0.342 mL · min(-1) · g(-1) in the subepicardium (P < .001). MBF during vasodilation was augmented to a greater extent at the subepicardial level (subendocardium vs subepicardium: 3.88 ± 0.86 vs 4.14 ± 0.88 mL · min(-1) · g(-1), P = .013). The endocardial-to-epicardial MBF ratio decreased significantly during hyperaemia (1.35 ± 0.23 to 1.12 ± 0.20, P < .001). Hyperaemic transmural MBF was inversely correlated with left ventricular end-diastolic volume index (LVEDVI) (r (2) = 0.41, P = .0003), with greater impact however at the subendocardial level. CONCLUSIONS (15)O-labeled water PET enables MBF measurements with distinction of the subendocardial and subepicardial layers in the normal human heart and correlates with LVEDVI. This PET technique may prove useful in evaluating patients with signs of ischaemia due to coronary artery disease or microvascular dysfunction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantification of subendocardial and subepicardial blood flow using 15O-labeled water and PET: experimental validation.

UNLABELLED The purpose of this study was to assess the feasibility and accuracy of quantifying subendocardial and subepicardial myocardial blood flow (MBF) and the relative coronary flow reserves (CFR) using (15)O-labeled water (H(2)(15)O) and 3-dimensional-only PET. METHODS Eight pigs were scanned with H(2)(15)O and (15)O-labeled carbon monoxide (C(15)O) after partially occluding the circumf...

متن کامل

Impact of anatomical and functional severity of coronary atherosclerotic plaques on the transmural perfusion gradient: a [15O]H2O PET study.

BACKGROUND Myocardial ischaemia occurs principally in the subendocardial layer, whereas conventional myocardial perfusion imaging provides no information on the transmural myocardial blood flow (MBF) distribution. Subendocardial perfusion measurements and quantification of the transmural perfusion gradient (TPG) could be more sensitive and specific for the detection of coronary artery disease (...

متن کامل

Impairment of subendocardial perfusion reserve and oxidative metabolism in nonischemic dilated cardiomyopathy.

BACKGROUND Cardiac magnetic resonance (CMR) and [(11)C]acetate positron emission tomography (PET) were used to assess the hypothesis that patients with nonischemic dilated cardiomyopathy (NIDCM) have decreased subendocardial perfusion reserve and impaired oxidative metabolism, consistent with the concept of "energy starvation" in heart failure (HF). METHODS AND RESULTS CMR myocardial perfusio...

متن کامل

Delineation of impaired regional myocardial perfusion by positron emission tomography with H2(15)O.

Positron emission tomography with 15O-labeled water (H2(15)O) can be used to delineate abnormal regional myocardial blood flow in experimental animals. To determine the feasibility of this method in humans, we studied 33 subjects (9 normal volunteers and 24 patients with angiographically documented coronary artery disease) at rest and after myocardial hyperemia induced with intravenous infusion...

متن کامل

Direct comparison of [13N]ammonia and [15O]water estimates of perfusion with quantification of regional myocardial blood flow by microspheres.

BACKGROUND Both [13N]ammonia and [15O]water have been used to quantify myocardial blood flow with positron emission tomography using appropriate tracer kinetic models. A direct comparison of the two tracers with radioactive microspheres has not been performed in the same experimental preparation. METHODS AND RESULTS The two tracers have been tested for myocardial blood flow quantification in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2011