Original Contribution Potential IncreasedRisk of Ischemic Heart DiseaseMortalityWith Significant Dose Fractionation in the Canadian Fluoroscopy Cohort Study

نویسندگان

  • Lydia B. Zablotska
  • Mark P. Little
  • Jack Cornett
چکیده

Risks of noncancer causes of death, particularly cardiovascular disease, associated with exposures to high-dose ionizing radiation, are well known. Recent studies have reported excess risk in workers who are occupationally exposed to low doses at a low dose rate, but the risks of moderately fractionated exposures, such as occur during diagnostic radiation procedures, remain unclear. The Canadian Fluoroscopy Cohort Study includes 63,707 tuberculosis patients exposed to multiple fluoroscopic procedures in 1930–1952 and followed-up for death from noncancer causes in 1950–1987. We used a Poisson regression to estimate excess relative risk (ERR) per Gy of cumulative radiation dose to the lung (mean dose = 0.79 Gy; range, 0–11.60). The risk of death from noncancer causes was significantly lower in these subjects compared with the Canadian general population (P < 0.001). We estimated small, nonsignificant increases in the risk of death from noncancer causes with dose. We estimated an ERR/Gy of 0.176 (95% confidence interval: 0.011, 0.393) (n = 5,818 deaths) for ischemic heart disease (IHD) after adjustment for dose fractionation. A significant (P = 0.022) inverse dose fractionation effect in dose trends of IHD was observed, with the highest estimate of ERR/Gy for those with the fewest fluoroscopic procedures per year. Radiation-related risks of IHD decreased significantly with increasing time since first exposure and age at first exposure (both P < 0.05). This is the largest study of patients exposed to moderately fractionated low-to-moderate doses of radiation, and it provides additional evidence of increased radiation-associated risks of death from IHD, in particular, significantly increased radiation risks from doses similar to those from diagnostic radiation procedures. The novel finding of a significant inverse dose-fractionation association in IHD mortality requires further investigation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of Maximum Entrance Skin Dose of Patients Undergoing Cardiac Interventional Procedures and Its Correlation with Other Dosimetric Parameters

Introduction: In recent years, the number of complex coronary angiography (CA) is increasing rapidly. These procedures have a significant contribution to medical exposure to the general population. Exposure of patients to high doses of x-rays could cause deterministic effects on the skin. Therefore, the assessment of radiation doses of patients is of great importance. ...

متن کامل

Hematocrit level in patients with stroke or ischemic heart disease,Khorasan, 2002-2003

Introduction: Elevated hematocrit is associated with high blood viscosity and could lead to vascular thrombosis. The purpose of this study is to compare hematocit of ischemic stroke and myocardial infarction patients. Methods: All of the patients with ischemic stroke and myocardial infarction (MI) admitted in Vali-e-asr Hospital, Khorasan during 2002-2003 enrolled in this descriptive analytic...

متن کامل

The Contribution of VKORC1 and CYP2C9 Genetic Polymorphisms and Patients’ Demographic Characteristics with Warfarin Maintenance Doses: A Suggested Warfarin Dosing Algorithm

The requirement of varying doses of warfarin for different individuals can be explained by environmental and genetic factors. We evaluated the frequency of vitamin K epoxide reductase complex subunit 1 (VKORC1) and cytochrome P450 2C9 (CYP2C9) variants together with patientdemographic characteristics and investigated their association with warfarin dose requirement with the ob...

متن کامل

The Contribution of VKORC1 and CYP2C9 Genetic Polymorphisms and Patients’ Demographic Characteristics with Warfarin Maintenance Doses: A Suggested Warfarin Dosing Algorithm

The requirement of varying doses of warfarin for different individuals can be explained by environmental and genetic factors. We evaluated the frequency of vitamin K epoxide reductase complex subunit 1 (VKORC1) and cytochrome P450 2C9 (CYP2C9) variants together with patientdemographic characteristics and investigated their association with warfarin dose requirement with the ob...

متن کامل

Evaluation of Patients’ Exposure during Angiography and Angioplasty Procedures in the Angiography Department of Shahid Madani Hospital in Tabriz

Introduction: Coronary angiography and angioplasty procedures lead to significant radiation exposure of patients. In the current study, the average radiation dose to patients during angiography in the Angiography Department of Shahid-Madani Hospital was determined. Materials and Methods: An image intensifier based angiography unit (Philips BH 3000) was used for angiography procedures. The accur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013