Randomized comparison of in vivo performance of two point-of-care tear film osmometers
نویسندگان
چکیده
PURPOSE To compare the in vivo precision of two commercially available point-of-care osmometers among normal subjects with no dry eye disease. METHODS Twenty healthy adults with healthy ocular surfaces were evaluated by licensed eye care practitioners. All subjects had low Ocular Surface Disease Index score (<5), normal tear breakup time (>10 seconds), and no evidence of corneal fluorescein staining. Five consecutive measurements of tear osmolarity were measured on each eye using each of the two osmometers: the TearLab Osmolarity System (TearLab) and the I-Med i-Pen (i-Pen), for a total of 200 measurements per device. Performance of the osmometers was determined by specificity, estimated by the percentage of osmolarity data at or below the clinical cutoff (308 mOsm/L) and precision, and represented by the standard deviation per subject. In addition, to assess analytical performance, on each day of patient testing, standardized osmolarity quality control solutions (338 mOsm/L) were tested on the TearLab per manufacturer instructions. i-Pen manufacturer instructions do not neither provide for, nor recommend quality control procedures. RESULTS The mean age of the 20 subjects was 27±8 years (range: 19-48 years, 16 females, four males). Over 2 months of testing, the TearLab reported analytical performance on quality control solutions of 335.8±4.2 mOsm/L with a coefficient of variation of 1.3%. In the subject cohort, 90.9% of TearLab measurements were in the normal range ≤308 mOsm/L. The i-Pen reported 37.5% of all measurements in the normal range. The average intra-subject osmolarity of the TearLab was 295.4±8.6 mOsm/L, which was significantly lower and less variable than the i-Pen, which reported an average of 319.4±20.3 mOsm/L (P<0.001). When the measurements were grouped by subject, the TearLab accurately identified 100% of subjects as normal while the i-Pen accurately identified only 15% of subjects as normal. CONCLUSION In this randomized comparative study of two point-of-care osmometers among normal, healthy non-dry eye subjects, the TearLab Osmolarity System demonstrated accuracy, precision, and agreement with clinical interpretation in line with the manufacturer claims. The i-Pen lacked sufficient performance to delineate subjects with and without dry eye disease.
منابع مشابه
Randomized, masked, in vitro comparison of three commercially available tear film osmometers
PURPOSE The purpose of this study was to compare the precision and accuracy of commercially available tear film osmometers. METHODS Contrived tear solution target values representing the physiological range of tear osmolarity (normal eyes 297 mOsm/L, moderately dry eyes 342 mOsm/L, and severe dry eyes 383 mOsm/L) were constructed using a mix of mono- and divalent electrolytes, metabolites, se...
متن کاملEvaluation of tear strength of two types of Iralgin and its comparison with similar alginate impression material
Objective: Among the various impression materials, for alginate tear strength is probably more important than the compressive strength. The tear strength is important when an impression involves a mechanical undercut and/or lacks bulk strength to resist tearing. This study evaluated tear strength of Iralgin and compared it with tear strength of Alginoplast. Methods: In this invitro experime...
متن کاملComparison of hyaluronic acid-containing topical eye drops with carbomer-based topical ocular gel as a tear replacement in canine keratoconjunctivitis sicca: A prospective study in twenty five dogs
The aim of this study was to evaluate the efficacy of a hyaluronic acid containing eye drop in ameliorating ocular surface pathology and discomfort in canine keratoconjunctivitis sicca (KCS). Twenty five dogs with KCS treated with a topical carbomer (CA)-based tear replacement gel were moved to treatment with a hyaluronic acid (HA)-containing tear replacement eye drop. Dogs were subject to a fu...
متن کاملPectin Film Coated Pellets for Colon-targeted Delivery of Budesonide: In-vitro/in-vivo Evaluation in Induced Ulcerative Colitis in Rat
Abstract The main objective of this study was to prepare colon-specific pellets of budesonide using pectin as film coating. Pellet cores of budesonide were prepared by extrusion / spheronization technique. Pectin, in different ratios was combined with Eudragit RS30D, Eudragit NE30D or Surelease to produce film coating. The dissolution profiles of pectin coated pellets were investigated in pH o...
متن کاملPectin Film Coated Pellets for Colon-targeted Delivery of Budesonide: In-vitro/in-vivo Evaluation in Induced Ulcerative Colitis in Rat
Abstract The main objective of this study was to prepare colon-specific pellets of budesonide using pectin as film coating. Pellet cores of budesonide were prepared by extrusion / spheronization technique. Pectin, in different ratios was combined with Eudragit RS30D, Eudragit NE30D or Surelease to produce film coating. The dissolution profiles of pectin coated pellets were investigated in pH o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 11 شماره
صفحات -
تاریخ انتشار 2017