Ultratrace analysis of Antarctic snow samples by reaction cell inductively coupled plasma mass spectrometry using a total-consumption micro-sample-introduction system.

نویسندگان

  • Marco Grotti
  • Francesco Soggia
  • Josè Luis Todolì
چکیده

In this work, a new sensitive procedure for the determination of ultratrace elements in snow samples based on quadrupole ICP-MS has been developed. After filtration through a 0.5 microm PTFE membrane (for dissolved element determination) or acidification with 0.5% nitric acid (for acid dissolvable element determination), the analytes were preconcentrated by sample volume reduction and analysed by ICP-MS. Micro-samples were efficiently introduced into the plasma source at 20 microl min(-1) uptake rate by using a PFA micronebulizer coupled to an evaporation chamber of the torch integrated sample introduction system (TISIS). As a result, the amount of sample required was about one order of magnitude lower than that required with a conventional liquid sample introduction system. In order to improve the transport efficiency, the TISIS chamber was electrically-heated at 70 degrees C and a sheathing gas stream was used to protect the aerosol from the chamber walls. Under these conditions, negative solvent plasma effects were no more severe than for conventional systems, because the total solvent plasma load was 20 mg min(-1). The operating parameters were optimized to obtain maximum sensitivity, while limiting oxides and double charge ion formation. The polyatomic interferences were removed by applying the dynamic reaction cell (DRC) technique, using ammonia as the reaction gas. Under the optimized conditions, limits of detection ranged from 0.02 to 4.5 pg g(-1), allowing the determination of Cr, V, Fe, Mn, Pb, Zn, Cd, Co and Cu in Antarctic snow samples. Signal repeatability was lower than 10% which prevented the use of an internal standard. Precision of the procedure ranged from 2.0% to 5.6%. The accuracy of the method was verified by the analysis of both certified reference water and surface snow samples collected in coastal and inland areas of Antarctica. The DRC program used, the short wash out and signal stabilization times registered under these conditions led to a 10 h(-1) sample throughput.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The ultratrace determination of iodine 129 in aqueous samples using the 7700x ICP-MS with oxygen reaction mode

Determination of the radionuclide iodine 129 using ICP-MS has been improved by the use of an Octopole Reaction System (ORS) ICP-MS, operated in oxygen cell mode. Oxygen reaction gas removes the background signal at m/z 129, which is due to the presence of Xe as an impurity in the Ar plasma gas and to the polyatomic ion IH2. NIST SRM standards with different 129I/127I ratios and at multiple conc...

متن کامل

Ultratrace determination of Pb, Se and As in wine samples by electrothermal vaporization inductively coupled plasma mass spectrometry.

The determination of Pb, Se and As in wine has a great interest due to health risks and legal requirements. To perform the analysis of wine, two considerations must be taken into account: (i) the low concentration level of the analytes; and (ii) the risk of interferences due to wine matrix components. The goal of this work is to evaluate electrothermal vaporization (ETV) sample introduction for...

متن کامل

Measurement of the Trace Elements Cu, Zn, Fe, and Mg and the Ultratrace Elements Cd, Co, Mn, and Pb in Limited Quantity Human Plasma and Serum Samples by Inductively Coupled Plasma-Mass Spectrometry

In public health studies limited volumes of blood are often collected and stored for future hypothesis testing. Archived samples are irreplaceable and therefore it is valuable to develop analytical techniques that require minimal sample volume. This work describes the measurement of trace elements Mg, Cu, Fe, Zn and ultratrace elements Cd, Co, Mn, Pb in limited quantity (150 μL) human serum or ...

متن کامل

State-of-the-art in inorganic mass spectrometry for analysis of high-purity materials

Inorganic mass spectrometric methods are widely used for the multielemental determination of elements at the trace and ultratrace level in high-purity materials (e.g., conducting, semiconducting and nonconducting solid samples, high-purity water, organic solutions and solvents). Inductively coupled plasma mass spectrometry (ICP-MS), laser ablation inductively coupled plasma mass spectrometry (L...

متن کامل

Inorganic trace analysis by mass spectrometry

Mass spectrometric methods for the trace analysis of inorganic materials with their ability to provide a very sensitive multielemental analysis have been established for the determination of trace and ultratrace elements in high-purity materials (metals, semiconductors and insulators), in different technical samples (e.g. alloys, pure chemicals, ceramics, thin films, ionimplanted semiconductors...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Analyst

دوره 133 10  شماره 

صفحات  -

تاریخ انتشار 2008