Device diagnostics and long-term clinical outcome in patients receiving cardiac resynchronization therapy.
نویسندگان
چکیده
AIMS This retrospective analysis sought to develop and validate a model using the measured diagnostic variables in cardiac resynchronization therapy (CRT) devices to predict mortality. METHODS AND RESULTS Data used in this analysis came from two CRT studies: Cardiac Resynchronization Therapy Registry Evaluating Patient Response with RENEWAL Family Devices (CRT RENEWAL) (n = 436) and Heart Failure-Heart Rate Variability (HF-HRV) (n = 838). Patients from CRT RENEWAL were used to create a model for risk of death using logistic regression and to create a scoring system that could be used to predict mortality. Results of both the logistic regression and the clinical risk score were validated in a cohort of patients from the HF-HRV study. Diagnostics significantly improved over time post-CRT implant (all P < 0.001) and were correlated with a trend of decreased risk of death. The regression model classified CRT RENEWAL patients into low (2.8%), moderate (6.9%), and high (13.8%) risk of death based on tertiles of their model predicted risk. The clinical risk score classified CRT RENEWAL patients into low (2.8%), moderate (10.1%), and high (13.4%) risk of death based on tertiles of their score. When both the regression model and the clinical risk score were applied to the HF-HRV study, each was able to classify patients into appropriate levels of risk. CONCLUSION Device diagnostics may be used to create models that predict the risk of death.
منابع مشابه
Cystatin C as a predictor of mortality and cardiovascular morbidity after cardiac resynchronization therapy.
BACKGROUND Cardiac resynchronization therapy (CRT) has been reported to improve symptoms and cardiac performance in patients with severe heart failure (HF), but CRT recipients with advanced HF do not always experience improved mortality rates. Cystatin C has recently been involved in HF, but the association of serum cystatin C level with adverse events and long-term prognosis after CRT is unkno...
متن کاملSerum albumin levels predict clinical outcomes in chronic kidney disease (CKD) patients undergoing cardiac resynchronization therapy.
OBJECTIVE A low level of serum albumin is common in chronic kidney disease (CKD) patients with heart failure (HF). Cardiac resynchronization therapy (CRT), a novel therapeutic option, improves cardiac performance in patients with severe HF. In addition, CKD has recently been found to be associated with outcomes after CRT; however, the associations of the serum albumin levels with adverse events...
متن کاملEchocardiographic measures of acute haemodynamic response after cardiac resynchronization therapy predict long-term clinical outcome.
AIMS Although acute haemodynamic improvement in response to cardiac resynchronization therapy (CRT) is reflective of a favourable cardiac contractile response, there is limited information regarding not only its ability to predict long-term clinical outcome but also cardiac-substrate-specific differences in the prognostic value of this measure. METHODS AND RESULTS Fifty-three heart failure pa...
متن کاملLong-Term Echocardiographic Response to Cardiac Resynchronization Therapy in Initial Nonresponders.
OBJECTIVES The aim of this study was to investigate the frequency and clinical implications of a delayed echocardiographic response to cardiac resynchronization therapy (CRT). BACKGROUND Long-term prognosis for CRT patients is routinely based on the assessment of echocardiograms after 6 to 12 months of therapy. Some patients, however, may require a longer period of therapy before echocardiogr...
متن کاملArrhythmia/Electrophysiology Long-Term Outcome After ICD and CRT Implantation and Influence of Remote Device Follow-Up The ALTITUDE Survival Study
Background—Outcome data for patients receiving implantable cardioverter-defibrillator (ICD) and cardiac resynchronization therapy– defibrillator (CRT-D) devices treated outside of clinical trials are lacking. No clinical trial has evaluated mortality after device implantation or after shock therapy in large numbers of patients with implanted devices that regularly transmit device data over a ne...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
دوره 11 12 شماره
صفحات -