Permanently Implanted Transvenous

نویسندگان

  • MALCOLM M. MCHENRY
  • EDWARD A. SMELOFF
چکیده

Three patients with complete heart block had a high resistance to electrical stimulation of the endocardium through transvenous pacemaker systems. One patient died; one needed reoperation for implantation of epicardial electrodes; and the third required a generator of higher current. The present enthusiasm for permanent transvenous implantation of pacemakers must be tempered somewhat by the knowledge that high endocardial resistance to pacing represents another cause of failure. Simple and rapid methods of determining the current necessary to stimulate the endocardium are available and should be used prior to permanent implantation of the generator. If a substantial margin of safety does not exist, one should consider substituting a pulse generator with greater output or an epicardial electrode system.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Permanently implanted transvenous pacemakers. Electrical measurements of function.

Three patients with complete heart block had a high resistance to electrical stimulation of the endocardium through transvenous pacemaker systems. One patient died; one needed reoperation for implantation of epicardial electrodes; and the third required a generator of higher current. The present enthusiasm for permanent transvenous implantation of pacemakers must be tempered somewhat by the kno...

متن کامل

Permanently Implanted Transvenous Pacemakers

Three patients with complete heart block had a high resistance to electrical stimulation of the endocardium through transvenous pacemaker systems. One patient died; one needed reoperation for implantation of epicardial electrodes; and the third required a generator of higher current. The present enthusiasm for permanent transvenous implantation of pacemakers must be tempered somewhat by the kno...

متن کامل

Permanent ventricular pacemakers. Comparison of transthoracic and transvenous implantation.

In the series of 86 patients with the Stokes-Adams syndrome or with symptomatic bradycardia managed with permanently implanted ventricular pacemakers reported on, 35 patients had primary implantation of epicardial leads at thoracotomy and 51 had transvenous endocardial electrodes passed via the jugular venous system for permanent ventricular pacing. The transvenous method of permanent pacemaker...

متن کامل

Long term transvenous ventricular pacing in adults with congenital abnormalities of the heart and great arteries.

Improved techniques of transvenous pacing have made it possible to use this approach in various congenital cardiac abnormalities. Transvenous active fixation pacing leads were implanted in seven patients aged 15 to 81 years with abnormal venous, atrioventricular, or ventriculoarterial connections with successful ventricular pacing.

متن کامل

Percutaneous transvenous mitral annuloplasty: initial human experience with device implantation in the coronary sinus.

BACKGROUND Mitral annuloplasty is the most common surgical procedure performed for ischemic mitral regurgitation (MR). Surgical mitral annuloplasty is limited by morbidity, mortality, and MR recurrence. We evaluated the safety and feasibility of a transvenous catheter-delivered implantable device to provide a percutaneous alternative to surgical mitral annuloplasty. METHODS AND RESULTS Five p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005