چکیده

Numerical simulation is extensively used in heat exchanger design and performance evaluation. While evaluating potential working fluids, pure fluids and fluid mixtures with different component combinations and fractions are compared based on simulation results. Two of the challenges while conducting such studies are the uncertainties of refrigerant properties and the applicability of empirical heat transfer and pressure drop correlations. Pure refrigerant property uncertainties are associated with experimental testing technique. The uncertainties of refrigerant mixtures are significantly higher when mixing rules are applied due the lack of measured data. Most of the empirical correlations are developed for certain refrigerants with a limited range of applicability of fluid states and tube geometry. Therefore, it is essential to understand the uncertainties in heat transfer coefficient and pressure drop calculations with different fluids. This paper presents a sensitivity analysis of heat transfer and pressure drop correlations for both in-tube condensation and evaporation cases. Multiple refrigerant such as R1234yf, R1234ze(E), R134a, R32, R410A, R445A, D2Y60 and L41a are analyzed based on commonly used heat transfer and pressure drop correlations from the literature. The parameters of the analysis are the thermodynamic and transport properties of the refrigerants. This study should be helpful to researchers and engineers in correlation selection during heat exchanger simulation and in understanding the potential prediction uncertainties while evaluating new fluids.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of hemispherical chevrons angle, depth, and pitch on the convective heat transfer coefficient and pressure drop in compact plate heat exchangers

Plate heat exchangers are widely used in industries due to their special characteristics, such as high thermal efficiency, small size, light weight, easy installation, maintenance, and cleaning. The purpose of this study is to consider the effect of depth, angle, and pitch of hemispheric Chevrons on the convective heat transfer coefficient and pressure drop. In the simulation of the heat ex...

متن کامل

The effect of hemispherical chevrons angle, depth, and pitch on the convective heat transfer coefficient and pressure drop in compact plate heat exchangers

Plate heat exchangers are widely used in industries due to their special characteristics, such as high thermal efficiency, small size, light weight, easy installation, maintenance, and cleaning. The purpose of this study is to consider the effect of depth, angle, and pitch of hemispheric Chevrons on the convective heat transfer coefficient and pressure drop. In the simulation of the heat ex...

متن کامل

Condensation of Natural Refrigerant Mixtures in Horizontal Smooth Tube - Prediction Model and Calculation Results

This paper deals with the heat exchange performance prediction of a counter flow double-tube condenser for binary natural refrigerant mixtures (propane/n-butane & propane/i-butane ). The local characteristics of the heat transfer and pressure drop are calculated using a prediction method developed by authors, and the total pressure drop, the overall heat transfer coefficient and the average hea...

متن کامل

Hydraulic Network Modeling to Analyze Stream Flow Effectiveness on Heat Transfer Performance of Shell and Tube Heat Exchangers

In this article, stream flow effectivness is based on hydraulic network studied in the shell-side of a shell and tube heat exchange as a case study. For an appropriate heat exchangers rating design to meet a specified duty, it's better to consider each stream flow separately. Using the hydraulic network principals, a set of the correlations for calculating different stream flow rates in the cro...

متن کامل

Experimental study of nanofluid effects on heat transfer in closed cycle system in shell and tube heat exchangers at Isfahan power plant

The present study investigated the effect of distilled-water/ silver nanofluid on heat transfer in a closed cooling system of one of the electrical energy generation units at Isfahan power plant. The difference between this study and previous researches refers to silver properties which have a high thermal conductivity and is non-toxic, hydrophilic and eco-friendly. Distilled water/ silver ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014