Glucose infusion test (GIT) compared with the saline dilution technology in recirculation measurements.

نویسندگان

  • Alberto Magnasco
  • Sandro Alloatti
چکیده

BACKGROUND Glucose infusion test (GIT) is a new method to measure vascular access recirculation (R) based on basal glucose increase in the arterial blood line after a 20% glucose bolus (5 ml) into the venous chamber. METHODS We compared GIT with the ultrasound dilution method (HD01, Transonic Systems Inc., USA) in a circuit reproducing in vitro the phenomenon of R. We repeated the comparison in 162 chronic haemodialysis patients (133 fistulae, 17 central venous catheters, 12 prosthetic grafts). RESULTS In vitro, we determined the timing for C2 sampling: QB 200 ml/min, C2 16-20 s; QB 300 ml/min, C2 13-17 s; QB 400 ml/min, C2 9-12 s. GIT showed no false positives nor false negatives (100% specificity and sensitivity) while HD01 did not recognize three cases with R=5% (91% sensitivity) and it yielded no false positive (100% specificity). The Bland-Altman analysis showed a bias of 0.2+/-1.3% and 1.3+/-2.9% for GIT and HD01, respectively. In vivo, only 16 out of 162 patients were found positive with both methods (GIT 13.5+/-13%; HD01 16.3+/-15%; P=NS) while three patients with minimal R (GIT 3.2%) were not recognized by HD01 although a low R peak was clearly evident and repeatable on the laptop plot. The Bland-Altman analysis showed an overall bias of 0.2+/-1.7% to the limits of agreement=-3.1 and 3.6% (n=162) and no correlation between the difference and the mean of positive tests. The pooled coefficient of variation of positive cases was 13.3 and 18.1% for GIT and HD01, respectively. DISCUSSION Our in vitro study showed a good performance of GIT and its better sensitivity compared to HD01. These results were confirmed in vivo with only 3/162 discordant results due to a low R under the HD01 limit of detection (R=5%). In conclusion, the GIT proved to be a very accurate screening test for R, with a very low threshold of detection. In addition, it is simple, user-friendly and inexpensive.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurements of recirculation during neonatal veno-venous extracorporeal membrane oxygenation: clinical application of the ultrasound dilution technique.

Recirculation during dual lumen veno-venous (DLVV) extracorporeal membrane oxygenation (ECMO) is a dynamic event that results in a fraction of the oxygenated blood exiting the arterial lumen and immediately shunting back into the venous lumen. Excessive recirculation will result in suboptimal oxygen delivery to the patient. Ultrasound dilution is a technology that has been shown to rapidly quan...

متن کامل

Validation of haemodialysis recirculation and access blood flow measured by thermodilution.

BACKGROUND Recirculation (R) and access blood flow (Qac) measurements are considered useful indicators of adequate delivery of haemodialysis. It was the purpose of this study to compare measurements of R and Qac obtained by two different techniques which are based on the same principle of indicator dilution, but which differ because of the characteristics of the injection and detection of the d...

متن کامل

Designing a glycemic control strategy to maintain glucose homeostasis and prevent hypoglycemia for subjects with type 1 diabetes

This paper presents using the fractional PImDn controller module which manipulates insulin infusion rate to maintain normoglycemia in subjects with type 1 diabetes. To prevent severe hypoglycemia, a conventional proportional controller is used to regulate glucagon infusion rate when the blood glucose levels fall below a threshold. Two sets of controller parameters are obtained and evaluated. Fo...

متن کامل

The effects of short term intravenous infusion of a soybean based lipid emulsion on some blood constituents in sheep: A preliminary study

To evaluate the effect of intravenous infusion of a soybean based lipid emulsion (Lipovenoes 10%) on some blood constituents in sheep, a replicated 2 × 2 Latin square design experiment was conducted in four clinically healthy ewes. Lipid emulsion (LE group) or normal saline (NS group) was infused intravenously at a rate of 0.025 mL kg-1 per min for 6 hr and the concentrations of bloo...

متن کامل

Dilution and redistribution effects of rapid 2-litre infusions of 0.9% (w/v) saline and 5% (w/v) dextrose on haematological parameters and serum biochemistry in normal subjects: a double-blind crossover study.

Although hypoalbuminaemia after injury may result from increased vascular permeability, dilution secondary to crystalloid infusions may contribute significantly. In this double-blind crossover study, the effects of bolus infusions of crystalloids on serum albumin, haematocrit, serum and urinary biochemistry and bioelectrical impedance analysis were measured in healthy subjects. Ten male volunte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association

دوره 21 11  شماره 

صفحات  -

تاریخ انتشار 2006