Comparisons of the Effects of Stent Eccentricity on the Neointimal Hyperplasia between Sirolimus-Eluting Stent versus Paclitaxel-Eluting Stent

نویسندگان

  • Byeong-Keuk Kim
  • Young-Guk Ko
  • Seungjin Oh
  • Jung-Sun Kim
  • Woong Chol Kang
  • Dong Woon Jeon
  • Joo Young Yang
  • Donghoon Choi
  • Myeong-Ki Hong
  • Taehoon Ahn
  • Yangsoo Jang
چکیده

PURPOSE Previous studies suggested that asymmetric stent expansion did not affect suppression of neointimal hyperplasia (NIH) after sirolimus-eluting stents (SES) implantation. The aim of this study was to evaluate the effects of stent eccentricity (SE) on NIH between SES versus paclitaxel-eluting stents (PES) using an intravascular ultrasound (IVUS) analysis from the randomized trial. MATERIALS AND METHODS Serial IVUS data were obtained from Post-stent Optimal Expansion (POET) trial, allocated randomly to SES or PES. Three different SE (minimum stent diameter divided by maximum stent diameter) were evaluated; SE at the lesion site with maximal %NIH area (SE-NIH), SE at the minimal stent CSA [SE-minimal stent area (SE-MSA)], and averaged SE through the entire stent (SE-mean). We classified each drug-eluting stents (DES) into the concentric (≥ mean SE) and eccentric groups (< mean SE) based on the mean value of SE. RESULTS Among 301 enrolled patients, 233 patients [SES (n = 108), PES (n = 125)] underwent a follow-up IVUS. There was no significant correlation between %NIH area and SE-NIH (r = - 0.083, p = 0.391) or SE-MSA (r = - 0.109, p = 0.259) of SES. However, SE-NIH of PES showed a weak but significant correlation with %NIH area (r = 0.269, p < 0.01). As to the associations between SEmean and NIH volume index, SES revealed no significant correlation (r = - 0.001, p = 0.990), but PES showed a weak but significant correlation (r = 0.320, p < 0.01). However, there was no difference in the restenosis rate between the eccentric versus concentric groups of both DES. CONCLUSION This study suggests that lower SE of both SES and PES, which means asymmetric stent expansion, may not be associated with increased NIH.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

نتایج بالینی پس از آنژیوپلاستی عروق کرونر، بروز حوادث بزرگ قلبی-عروقی و عوارض انواع استنت

Background: Cardiovascular diseases alone have become the leading cause of death worldwide. One of the treatment methods cardiovascular disease is angioplasty. This study aimed to investigate the clinical results after coronary artery angioplasty, based on the incidence of major cardiovascular events with emphasis on stent types. Methods: In this retrospective cross-sectional study, the preval...

متن کامل

Comparison of zotarolimus-eluting stents with sirolimus-eluting and paclitaxel-eluting stents: intimal hyperplasia and vascular changes assessed by volumetric intravascular ultrasound analysis.

BACKGROUND As a substudy of the large, randomized ZEST (Comparison of the Efficacy and Safety of Zotarolimus-Eluting Stent with Sirolimus-Eluting and PacliTaxel-Eluting Stent for Coronary Lesions) trial comparing first- and second-generation drug-eluting stents, we evaluated intimal hyperplasia (IH) and vascular changes using volumetric intravascular ultrasound analysis. METHODS AND RESULTS C...

متن کامل

Intravascular ultrasound results from the NEVO ResElution-I trial: a randomized, blinded comparison of sirolimus-eluting NEVO stents with paclitaxel-eluting TAXUS Liberté stents in de novo native coronary artery lesions.

BACKGROUND The NEVO sirolimus-eluting stent (NEVO SES) is a novel cobalt-chromium stent combining sirolimus release from reservoirs with bioabsorbable polymer to reduce spatial and temporal polymer exposure. The aim of this study was to assess the arterial response to the NEVO SES in a randomized, blinded comparison versus the surface-coated TAXUS Liberte paclitaxel-eluting stent (TAXUS Liberté...

متن کامل

Kommerell diverticulum associated with aberrant left subclavian artery and right-sided aortic arch.

SEARCH) study. Circulation 2004;109:1366–70. 30. Iijima R, Ndrepepa G, Mehilli J, Markwardt C, Bruskina O, Pache J et al. Impact of diabetes mellitus on long-term outcomes in the drug-eluting stent era. Am Heart J 2007;154:688–93. 31. Kawamoto T, Okura H, Koyama Y, Toda I, Taguchi H, Tamita K et al. The relationship between coronary plaque characteristics and small embolic particles during coro...

متن کامل

Drug-eluting stent update 2007: part I. A survey of current and future generation drug-eluting stents: meaningful advances or more of the same?

Analyst projections for the drug-eluting stent (DES) market estimated that the total number of DES implanted in 2010 would go beyond 4.5 million worldwide. Although the initial results seemed promising, longer-term follow-up in a broader range of patients revealed some pitfalls. Delayed neointimal growth, enhanced platelet aggregation, a local hypersensitivity reaction against the polymer coati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 51  شماره 

صفحات  -

تاریخ انتشار 2010