Evaluation of four hematology and a chemistry portable benchtop analyzers using non-human primate blood.

نویسندگان

  • C L Snider
  • E J Dick
  • D L McGlasson
  • M C Robbins
  • R L Sholund
  • Y R Bommineni
  • G B Hubbard
چکیده

BACKGROUND Near patient testing (NPT) and point-of-care testing (POCT) using portable benchtop analyzers has become necessary in many areas of the medical community, including biocontainment. METHODS We evaluated the Beckman AcT diff, Abaxis Vetscan HMII (two instruments), Abbott Cell-Dyn 1800, and Abaxis Vetscan VS2 for within-run precision and correlation to central laboratory instruments using non-human primates blood. RESULTS Compared with the central laboratory instruments, the Beckman AcT diff correlated on 80%; the HMII instruments on 31% and 44%, the CD1800 on 31%, and the VS2 on 71% of assays. For assays with published manufacturers precision guidelines, the AcT diff met all nine, the HMII instruments met one and six of six, and the CD 1800 met one of six. CONCLUSIONS Laboratories using NPT/POCT must test their individual instruments for precision and correlation, identify assays that are reliable, and exclude or develop supplemental procedures for assays that are not.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Niche for Microfluidics in Portable Hematology Analyzers

The complete blood count (CBC) has by and large remained confined to the traditional laboratory setting since its inception. Used in a variety of diagnostic assessments, the CBC has essentially become limited to clinical laboratories because of reliance on large automated hematology devices. With many potential uses at the point of care and clinical settings, as well as the research laboratory,...

متن کامل

Performance of two portable meters and a benchtop analyzer for blood glucose concentration measurement in rabbits.

OBJECTIVE To evaluate performance of a human portable blood glucose meter (PBGM), a veterinary PBGM, and a veterinary benchtop analyzer for measuring blood glucose concentration in rabbits and to evaluate the effect of sample characteristics on their performance. DESIGN Observational prospective cross-sectional study. SAMPLE Blood samples from 89 pet rabbits. PROCEDURES Blood glucose conc...

متن کامل

Peykan check, a simple continuous quality control method for hematology analyzers

A simple inexpensive con!nuous quality control method, by means of eight basic blood coun!ng parameters, obtained from automated hematology analyzers, using pa!ent samples, is described. A few samples with low, normal and high values were selected and introduced to the instrument early in the morning as the first count, the results of which are plo#ed on the appropriate chart as dots. The sa...

متن کامل

Evaluation of the i-STAT portable clinical analyzer in chickens (Gallus gallus).

The i-STAT portable clinical analyzer (PCA) was evaluated for performance in avian species. With the EG7+ cartridge, which provided results for hydrogen ion concentration, oxygen tension, carbon dioxide tension, sodium, potassium, ionized calcium, hematocrit, and various calculated parameters, analytical accuracy and precision were tested by comparing obtained values to those of established tra...

متن کامل

Simple Lactate Measurement in Horses Using a Portable Lactate Analyzer with Lancet Skin Punctures under Field Conditions

J. Equine Sci. Vol. 18, No. 1 pp. 5–11, 2007 The following items were investigated to measure blood lactate in horses under field conditions using portable lactate analyzers recently developed for human athletes. 1) The precision of two types of portable lactate analyzer and the standard analyzer using the immobilized enzyme method, and correlation among the lactate concentrations measured by t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of medical primatology

دوره 38 6  شماره 

صفحات  -

تاریخ انتشار 2009