Radioimmunoassay for free and conjugated urinary metanephrine.
نویسندگان
چکیده
We describe a convenient and specific radioimmunoassay for urinary metanephrine, in which we used an antiserum generated in rabbits by injecting with synephrine conjugated to bovine serum albumin as described by Grota and Brown [Endocrinology 98, 615 (1976)]. The antiserum is specific for metanephrine and epinephrine. Epinephrine cross reaction is minimized to 1% by adding 2 ng of epinephrine to each assay tube. Incubation time is 12 h. The sensitivity of the assay is 40 pg. Within-and between-assay coefficients of variation are 7.0 and 9.7%, respectively. We assayed first-voided morning urine and 24-h urine specimens from 15 normal subjects before and after acid hydrolysis, to assess total and free metanephrine concentrations. Mean (+/-SD) total and free urinary metanephrine excretion were 17 +/- 11 and 3.5 +/- 1.0 micrograms/24 h in these subjects; corresponding values for the morning specimens were 13.4 +/- 8.3 and 3.5 +/- 1.5 micrograms/liter, respectively.
منابع مشابه
Radioimmunoassay of metanephrine and normetanephrine for diagnosis of pheochromocytoma.
Sensitive and specific radioimmunoassays of metanephrine and normetanephrine were developed by use of 125I-labeled synephrine and specific metanephrine antibody, and 125I-labeled octopamine and specific normetanephrine antibody. Specific antibody for both metanephrine and normetanephrine was raised in rabbits by immunization with bovine serum albumin conjugated with the corresponding hapten, pr...
متن کاملUrinary metanephrine radioimmunoassay: comparison with the colorimetric assay.
A radioimmunoassay involving an 125I ligand has been developed and applied to the measurement of urinary metanephrine. To validate the clinical usefulness of this assay, we compared measurement of metanephrine by radioimmunoassay and of total urinary metanephrines by the Pisano colorimetric method. The radioimmunoassay is specific for metanephrine, whereas the colorimetric method measures both ...
متن کاملFree or total metanephrines for diagnosis of pheochromocytoma: what is the difference?
Pheochromocytomas, although a rare cause of hypertension, are dangerous tumors that require consideration in large numbers of patients. The resulting low prevalence of these tumors among the tested population and the inadequate sensitivity and specificity of commonly used biochemical tests make diagnosis of pheochromocytoma difficult and time-consuming. As outlined in two articles in this issue...
متن کاملThe Effects of Noise and Whole Body Vibration on Urinary Metanephrine and Normetanephrine
Background and Aim: Little attention has been paid to the effects of combined exposure to noise and vibration. Exposure to noise and vibration can effect stress hormones and may lead to high blood pressure and cardiovascular disorders. This study aims to investigate the effects of noise and vibration on urinary Metanephrine and Normetanephrine among men. Methods: In this experimental study, 30 ...
متن کاملLevodopa therapy in Parkinson's disease: influence on liquid chromatographic tandem mass spectrometric-based measurements of plasma and urinary normetanephrine, metanephrine and methoxytyramine.
BACKGROUND Medication-related interferences with measurements of catecholamines and their metabolites represent important causes of false-positive results during diagnosis of phaeochromocytomas and paragangliomas (PPGLs). Such interferences are less troublesome with measurements by liquid chromatography with tandem mass-spectrometry (LC-MS/MS) than by other methods, but can still present proble...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 23 7 شماره
صفحات -
تاریخ انتشار 1977