Measurement of persistence in YAG:Ce3+ scintillator with pulsed synchrotron X-rays

نویسندگان

  • Tatsuhito Matsuo
  • Naoto Yagi
چکیده

The decay time of YAG:Ce(3+) phosphor was studied using a CMOS camera with a frame rate of 1302000 s(-1) and pulsed X-rays from SPring-8. A high-resolution X-ray detector with YAG:Ce(3+) was used with the camera to view the focused beam from the helical undulator. Mismatch between the ring circulation time and the frame time gave rise to a periodic variation of beam intensity in successive frames. Analysis of data obtained with two bunch modes showed that the decay time of YAG:Ce(3+) was 60 ns. The variation of the beam positions in isolated bunches was small enough to be neglected in experiments using the focused beam. The results also show the possibility of an X-ray diffraction study at high time and space resolution.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Review of the Applications of Synchrotron Radiation in Archaeological Sciences

The scientific research regarding investigation, characterization and protection of the archeological specimens is manifested through a notable participation of multidisciplinary subjects and experts, scientists and archeometrists. One of the main principals which are considered by archaeometrists in the study of the precious specimens is the utilizing nondestructive methods. As an example, in ...

متن کامل

Recent developments in X-ray imaging with micrometer spatial resolution.

X-ray detectors for imaging with a spatial resolution in the micrometer and submicrometer range have been developed at synchrotron radiation sources since 1996. The detectors consist of a scintillator, a light microscopy optic and a charge-coupled device (CCD). The scintillator converts part of the X-ray stopped by a material into a visible-light image which is projected onto the CCD by the lig...

متن کامل

X-ray pulse wavefront metrology using speckle tracking.

An instrument allowing the quantitative analysis of X-ray pulsed wavefronts is presented and its processing method explained. The system relies on the X-ray speckle tracking principle to accurately measure the phase gradient of the X-ray beam from which beam optical aberrations can be deduced. The key component of this instrument, a semi-transparent scintillator emitting visible light while tra...

متن کامل

Applicability of self-activation of an NaI scintillator for measurement of photo-neutrons around a high-energy X-ray radiotherapy machine.

The applicability of the activation of an NaI scintillator for neutron monitoring at a clinical linac was investigated experimentally. Thermal neutron fluence rates are derived by measurement of the I-128 activity generated in an NaI scintillator irradiated by neutrons; β-rays from I-128 are detected efficiently by the NaI scintillator. In order to verify the validity of this method for neutron...

متن کامل

Femtosecond laser ablation of cadmium tungstate for scintillator arrays

Ultrafast pulsed laser ablation has been investigated as a technique to machine CdWO4 single crystal scintillator and segment it into small blocks with the aim of fabricating a 2D high energy X-ray imaging array. Cadmium tungstate (CdWO4) is a brittle transparent scintillator used for the detection of high energy X-rays and γ-rays. A 6 W Yb:KGW Pharos-SP pulsed laser of wavelength 1028 nmwas us...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2011