Automated analysis of three-dimensional stress echocardiography
نویسندگان
چکیده
Real-time three-dimensional (3D) ultrasound imaging has been proposed as an alternative for two-dimensional stress echocardiography for assessing myocardial dysfunction and underlying coronary artery disease. Analysis of 3D stress echocardiography is no simple task and requires considerable expertise. In this paper, we propose methods for automated analysis, which may provide a more objective and accurate diagnosis. Expert knowledge is incorporated via statistical modelling of patient data. Methods for identifying anatomical views, detecting endocardial borders, and classification of wall motion are described and shown to provide favourable results. We also present software developed especially for analysis of 3D stress echocardiography in clinical practice. Interobserver agreement in wall motion scoring is better using the dedicated software (96%) than commercially available software not dedicated for this purpose (79%). The developed tools may provide useful quantitative and objective parameters to assist the clinical expert in the diagnosis of left ventricular function.
منابع مشابه
The Nonlinear Bending Analysis for Circular Nano Plates Based on Modified Coupled Stress and Three- Dimensional Elasticity Theories
In this paper, the nonlinear bending analysis for annular circular nano plates is conducted based on the modified coupled stress and three-dimensional elasticity theories. For this purpose, the equilibrium equations, considering nonlinear strain terms, are calculated using the least energy potential method and solved by the numerical semi-analytical polynomial method. According to the previous ...
متن کاملThree-Dimensional Finite Element Analysis of Stress Intensity Factors in a Spherical Pressure Vessel with Functionally Graded Coating
This research pertains to the three-dimensional (3D) finite element analysis (FEA) of the stress intensity factors (SIFs) along the crack front in a spherical pressure vessel coated with functionally graded material (FGM). The vessel is subjected to internal pressure and thermal gradient. The exponential function is adopted for property of FGMs. SIFs are obtained for a wide variety of crack sha...
متن کاملAutomated border detection in three-dimensional echocardiography: principles and promises.
Several automated border detection approaches for three-dimensional echocardiography have been developed in recent years, allowing quantification of a range of clinically important parameters. In this review, the background and principles of these approaches and the different classes of methods are described from a practical perspective, as well as the research trends to achieve a robust method.
متن کاملValue of real-time three-dimensional adenosine stress contrast echocardiography in patients with known or suspected coronary artery disease.
AIM The aim of this study was to evaluate the feasibility of myocardial wall-motion and perfusion assessment using contrast echocardiography during real-time three-dimensional (RT3D) adenosine stress test, and compare its diagnostic accuracy with the two-dimensional (2D) method using coronary angiography as reference. METHODS AND RESULTS Patients with known or suspected coronary artery diseas...
متن کاملEffect of face-to-face training and pamphlets in reducing anxiety in 7-25 years old clients referred to echocardiography
Introduction: Echocardiography is a diagnostic test in that ultrasound waves are used for producing images of the heart muscle and valves. Echocardiography provides a series of useful information about the heart and its function for treatment purpose. It is especially useful for assessing valvular heart disease. Although it has no known side effect, but similar to any other medical procedure, i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 19 شماره
صفحات -
تاریخ انتشار 2011