Chronic Exposure to Static Magnetic Fields from Magnetic Resonance Imaging Devices Deserves Screening for Osteoporosis and Vitamin D Levels: A Rat Model

نویسندگان

  • Harun R. Gungor
  • Semih Akkaya
  • Nusret Ok
  • Aygun Yorukoglu
  • Cagdas Yorukoglu
  • Esat Kiter
  • Emin O. Oguz
  • Nazan Keskin
  • Gulcin A. Mete
  • Paul B. Tchounwou
چکیده

Technicians often receive chronic magnetic exposures from magnetic resonance imaging (MRI) devices, mainly due to static magnetic fields (SMFs). Here, we ascertain the biological effects of chronic exposure to SMFs from MRI devices on the bone quality using rats exposed to SMFs in MRI examining rooms. Eighteen Wistar albino male rats were randomly assigned to SMF exposure (A), sham (B), and control (C) groups. Group A rats were positioned within 50 centimeters of the bore of the magnet of 1.5 T MRI machine during the nighttime for 8 weeks. We collected blood samples for biochemical analysis, and bone tissue samples for electron microscopic and histological analysis. The mean vitamin D level in Group A was lower than in the other groups (p = 0.002). The mean cortical thickness, the mean trabecular wall thickness, and number of trabeculae per 1 mm2 were significantly lower in Group A (p = 0.003). TUNEL assay revealed that apoptosis of osteocytes were significantly greater in Group A than the other groups (p = 0.005). The effect of SMFs in chronic exposure is related to movement within the magnetic field that induces low-frequency fields within the tissues. These fields can exceed the exposure limits necessary to deteriorate bone microstructure and vitamin D metabolism.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی میزان مواجهه شغلی با میدان های مغناطیسی پایا واثرات بهداشتی آن در مراکز تصویر برداری تشدید مغناطیسی

 Background and aim:  Magnetic resonance imaging as one of the best medical scanning technique is considered to be the most important sources of static magnetic fields. The staffs of MRI ´s units frequently exposed to these static magnetic fields. This study aims to determine the occupational exposure level to mentioned field and its related health effects in MRI´s units.    Methods:  The occup...

متن کامل

Does Exposure to Static Magnetic Fields Generated by Magnetic Resonance Imaging Scanners Raise Safety Problems for Personnel?

MRI workers are occupationally exposed to static and time-varying gradient magnetic fields.  While the 24-hour time-averaged exposure to static magnetic fields is about a few mT, the maximum static field strength can be as high as 500 mT during patient setup. Over the past several years, our laboratory has performed extensive experiments on the health effects of exposure of animal models and h...

متن کامل

The modeling of induced current density in eyes from static magnetic fields produce by MR scanner

Introduction: Staff and patient Movement in static magnetic field MRI scanner induces current density in the human tissues, so cause biologic effects in people. The aim of this study was the Modelling of current density induced by moving individual with different velocities in static magnetic field of magnetic resonance imaging. Materials and Methods: current ...

متن کامل

The effect of 17 days exposure to static magnetic fields on the hypothalamic-pituitary-gonadal axis in the male rat

Power stations produce a range of magnetic fields more than 20 mT which are harmful to those working or living around them. Several investigators have reported an increased health risk due to exposure to electric and magnetic fields (EMF) at 50 and 60 Hz. Several studies have been reported especially with increased tumor incidence, effects on reproduction and development, and neural and behavio...

متن کامل

Static Coil Design Considerations for the Magnetic Resonance Imaging

One of the main challenges in developing magnetic resonance imaging (MRI) systems is to create a static coil that needs to generate magnetic field density along with the characteristics of optimal homogeneity and magnitude size. To do this, two N42 Block PMs are used and the iron core is designed and optimized in accordance with the dimensions of PM pieces using ANSYS Maxwell software. Then, al...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2015