Flameless Atomic Absorption Spectrometric Determination of Bismuth i n Sulfide Ores and Metallurgical Materials by Electrothermal Atomizatio
نویسنده
چکیده
منابع مشابه
Application of Ion - Imprinted Polymer Synthesized as New Sorbent for Preconcentration and Separation of Thallium (I) and Its Determination by Electrothermal Atomic Absorption Spectroscopy
At this study, thallium (I) ion-imprinted polymer, as a novel sorbent for Tl (I) and comparison with Tl(III) ion-imprinted polymer has been synthesized. This sorbent for preconcentration and solid-phase extraction of Tl(I) ions from aqueous solutions, used. Through preparing the binary complex of Tl(I) ions with 5, 7-dichloroquinoline-8-ol (DCQ) the particles of thallium (I) Ion-Imprinted P...
متن کاملCoprecipitation of trace metal ions in water with bismuth(III) diethyldithiocarbamate for an electrothermal atomic absorption spectrometric determination.
متن کامل
Determination of Cadmium by Electrothermal Atomic Absorption Spectrometry after its Separation and Preconcentration by Syringe to Syringe Dispersive Liquid Phase Microextraction-Solidified Floating Organic Drop
The application of syringe to syringe dispersive liquid phase microextraction-solidified floating organic drop was extended for the separation and preconcentration of trace amounts of cadmium ions from water and cereal samples. The extracted cadmium was quantified by electrothermal atomic absorption spectrometry. Factors affecting the complex formation as well as microextraction efficiency such...
متن کاملExtraction separation and electrothermal atomic absorption spectrometric determination of thallium in some sulfide minerals.
A method for thallium determination in some sulfide minerals (sphalerite, galena, orpiment and realgar) by electrothermal atomic absorption spectrometry has been proposed. Mineral samples were dissolved in a mixture of HNO3 and HCl. The effect of interfering elements (Zn, Pb and As) on the determination of Tl in the investigated minerals was studied. These investigations show that it is not pos...
متن کاملDEVELOPMENT OF A METHOD FOR ALUMINIUM DETERMINATION IN SERUM AND DIALYSIS FLUID BY FLAMELESS ATOMIC ABSORPTION WITH GRAPHITE FURNACE
Aluminium determination was carried out in serum and dialysis fluid by a simple and reliable method of nameless atomic absorption with graphite furnace . . No preparatory procedures are required for water and dialysis fluid. In this method serum was mixed with 0.2% HNO, to allow complete combustion of the samples in order to improve analytical precision. The method has a sensitivity of 15 p...