Erratum to: Comparison of the evolution of mechanical ventilation associated pneumonia (VAP) before the implantation of selective digestive decontamination (DDS) and after implantation of pneumonia zero program (NZ)
نویسندگان
چکیده
Erratum to: Comparison of the evolution of mechanical ventilation associated pneumonia (VAP) before the implantation of selective digestive decontamination (DDS) and after implantation of pneumonia zero program (NZ) Reference 1. Fernández Fernández et al (2015) Comparison of the evolution of mechanical ventilation associated pneumonia (VAP) before the implantation of selective digestive decontamination (DDS) and after implantation of pneumonia zero program (NZ). Intensive Care Medicine Experimental 3(Suppl 1):A706 permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
منابع مشابه
Comparison of the evolution of mechanical ventilation associated pneumonia (VAP) before the implantation of selective digestive decontamination (DDS) and after implantation of pneumonia zero program (NZ)
Methods Data from the ENVIN registration: 01.01.05 / 01.01.15. ICU with 10 beds. We start DDS (in 2009) before the NZ program was recommended by SEMICYUC. Import of DDS from a pharmacy which is performed by master formulates. Conduct training and educational campaign (presencial and by means of internet) to professionals of ICU (total of 58 people). Mandatory measures for the prevention of VAP:...
متن کاملعنوان: Impact of Care Program on Ventilator-Associated Pneumonia Incidence: A Clinical Trial
چکیده: Background: Ventilator-associated pneumonia (VAP) is one of the common problems in patients who are under mechanical ventilation and increases the hospitalization duration and treatment expenses. The current study was conducted to determine the impact of a care program on VAP. Methods: This clinical trial was performed on intubated patients who were under mechanical ventilation in Intens...
متن کاملDoes Re-intubation Increased Risk of Ventilator- Associated Pneumonia (VAP) in Pediatric Intensive Care Unit Patients?
Introduction:ventilator- associated pneumonia(VAP),as defined by the centers for disease control and prevention (CDC),is a pneumonia that occurs in a patient receiving mechanical ventilation that develops 48 hours or more after initiation of ventilation.re-intubation which occur within 72 hours of planned extubation may effect VAP incidence.the aim of this study was to determine VAP incidence i...
متن کاملReview Paper: The Bed Incline and Prevention of Ventilator-Associated Pneumonia
Background: Ventilator-Associated Pneumonia (VAP) is the most common nosocomial (hospital acquired) infection among patients undergoing mechanical ventilation. It increases mortality rate, duration of mechanical intubated ventilation, and hospitalization in the Intensive Care Units (ICUs). This review study aims to determine the proper gradient of a hospital bed in preventing VAP in patients ho...
متن کاملImpact of implementation of a ventilator-associated pneumonia prevention bundle that includes selective digestive decontamination in a southern region of Spain.
Methods On June 2010, a VAP prevention bundle was implemented in province of Murcia (Spain) This bundle included: appropriate airway secretions management, strict hand hygiene, cuff pressure control, oral hygiene with chlorhexidine, semi-recumbent positioning and selective decontamination of the digestive tract (SDD) with a short course of parenteral antibiotic. On april 2011 was implemented “N...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 4 شماره
صفحات -
تاریخ انتشار 2016