Concentrations of haptoglobin in bovine plasma determined by ELISA or a colorimetric method based on peroxidase activity.
نویسندگان
چکیده
The objective was to compare different procedures for determination of haptoglobin in bovine plasma. Nine Angus steers were vaccinated against Mannheimia haemolytica to stimulate an acute-phase response. Blood samples were collected immediately prior to vaccination (day 0), and on days 1, 3, 5, 7 and 10. Plasma samples were frozen in duplicates at -80 °C. One set of the duplicates was analysed for haptoglobin concentrations using a commercial ELISA kit. A day effect was detected (p < 0.01) because haptoglobin peaked on day 3 and returned to baseline on day 7 relative to vaccination. The second duplicate was analysed using a procedure that measures haptoglobin-haemoglobin complexing by estimating differences in peroxidase activity (CPPA) with results expressed as optical density. Further, based on the ELISA results, the plasma sample with the greatest haptoglobin concentration was also serially diluted into a plasma sample with negligible haptoglobin concentration from the same steer (1:1 through 1:1024 dilution). These dilutions were used within the CPPA method to generate a standard curve and estimate plasma haptoglobin concentrations (CPPA + STD). A linear standard curve was generated (r(2) = 0.99). A day effect similar to the ELISA method was detected for the CPPA and CPPA + STD methods (p < 0.01). Results obtained from CPPA and ELISA methods were positively correlated (r = 0.97; p < 0.01). The values generated by the CPPA + STD procedure were similar (p = 0.38) compared to the values generated by the ELISA method. In conclusion, assessing concentrations of haptoglobin in bovine plasma using the CPPA and CPPA + STD methods generate highly correlated or similar results, respectively, compared to ELISA. Therefore, the CPPA + STD and CPPA methods can be used as a less expensive alternative to ELISA to determine concentrations or monitor changes in plasma haptoglobin in bovine samples.
منابع مشابه
The Effect of Different Stabilizers on Stability of Horseradish Peroxidase- Bovine Serum Albumin-Aflatoxin B1, a Conjugated Tracer for Detection of Aflatoxin B1 in Immunoassay-Based Methods
Aflatoxins are a group of fungal toxic metabolites, which are contaminated certain food commodities. ELISA is one of the sensitive methods for detection of aflatoxins. Preparation and stabilizing of a proper conjugated tracer for detection of aflatoxins is probably the main step for designing an ELISA method. In current study, different stabilizers were applied to stabilize a newly prepared con...
متن کاملHeterotropic Effect of β-lactam Antibiotics on Antioxidant Property of Haptoglobin) 2-2(-Hemoglobin Complex
Haptoglobin (Hp) is a mammalian serum glycoprotein showing a genetic polymorphism with three types, 1-1, 2-2 and 1-2. Hp appears to conserve the recycling of heme-iron by forming an essentially irreversible but non-covalent complex with hemoglobin which is released into the plasma by erythrocyte lysis. As an important consequence, Haptoglobin-Hemoglobin complex (Hp-Hb) shows considerable antiox...
متن کاملHeterotropic Effect of β-lactam Antibiotics on Antioxidant Property of Haptoglobin) 2-2(-Hemoglobin Complex
Haptoglobin (Hp) is a mammalian serum glycoprotein showing a genetic polymorphism with three types, 1-1, 2-2 and 1-2. Hp appears to conserve the recycling of heme-iron by forming an essentially irreversible but non-covalent complex with hemoglobin which is released into the plasma by erythrocyte lysis. As an important consequence, Haptoglobin-Hemoglobin complex (Hp-Hb) shows considerable antiox...
متن کاملThe Effect of Different Stabilizers on Stability of Horseradish Peroxidase- Bovine Serum Albumin-Aflatoxin B1, a Conjugated Tracer for Detection of Aflatoxin B1 in Immunoassay-Based Methods
Aflatoxins are a group of fungal toxic metabolites, which are contaminated certain food commodities. ELISA is one of the sensitive methods for detection of aflatoxins. Preparation and stabilizing of a proper conjugated tracer for detection of aflatoxins is probably the main step for designing an ELISA method. In current study, different stabilizers were applied to stabilize a newly prepared con...
متن کاملBiochemical analysis of bovine (BosIndicus) seminal plasma
The aim of this study was to investigate the comparison between some seminal plasma parameters and age of the bull. Concentrations of various biochemical parameters like fructose, glucose, total proteins, albumin and inorganic ions including Na, K and Cl ions of seminal plasma of breeding Sahiwal bulls of different ageswere assessed. Methods: 40Sahiwal bullsdivided into 4 age groups.Semen (2ml ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of animal physiology and animal nutrition
دوره 97 3 شماره
صفحات -
تاریخ انتشار 2013