Interleaved Circuitry And Hybrid Control As Means To Reduce The Effects Of Flow Maldistribution

نویسندگان

  • Christian K. Bach
  • Eckhard A. Groll
  • James E. Braun
  • Travis Horton
  • Christian K. BACH
  • Eckhard A. GROLL
  • James E. BRAUN
  • W. Travis HORTON
چکیده

Flow maldistribution in evaporators can lead to significant degradation of capacity and efficiency of vapor compression equipment. A significant amount of work has previously been done to mend these issues. For variable air flow maldistribution, refrigerant compensation was proposed to reduce the performance degradation. For fixed air side maldistribution, refrigerant circuitry modifications were proposed to significantly reduce the effects of the maldistribution. However, no work has been found on modifying the refrigerant circuitry to make it less vulnerable to varying air side maldistribution. The purpose of this paper is to fill this gap in open literature. The performance of the new, interleaved circuitry approach and an active refrigerant flow control is compared to the standard circuitry for different cases of maldistribution. The results show that the interleaved circuitry recovers less of the performance losses than equalization of the exit superheats. However, the implementation cost in an actual system is expected to be significantly lower and the long term reliability is expected to be much better than for an active control approach.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Advanced Analysis of Dew Point Control Unit of Hybrid Refrigeration Systems in Gas Refineries

In this paper, an advanced analysis of a novel hybrid compression-absorption refrigeration system (HCARS) for natural gas dew point control unit in a gas refinery is presented. This unit separates the heavy hydrocarbon molecules in the natural gas, which is traditionally carried out by natural gas cooling in a compression refrigeration cycle (CRS). The power input required for the refrigeration...

متن کامل

Study the Performance of Hybrid Constructed Wetland with Pumice Substrate and Vetiver Plants in Urban Wastewater Treatment

One of the ways to reduce the amount of wastewater pollution is the use of constructed wetlands. In this research, the performance of a hybrid constructed wetland with pumice ore and vetiver plant on urban wastewater has been investigated. Hybrid wetlands with these specifications were constructed in the vicinity of wastewater treatment at the Isfahan University of Technology. To evaluate the p...

متن کامل

Direct Simulation Based Model-Predictive Control of Flow Maldistribution in Parallel Microchannels

Flow maldistribution, resulting from bubbles or other particulate matter, can lead to drastic performance degradation in devices that employ parallel microchannels for heat transfer. In this work, direct numerical simulations of fluid flow through a prescribed parallel microchannel geometry are performed and coupled with active control of actuated microvalves to effectively identify and reduce ...

متن کامل

Adaptive Observer-Based Decentralized Scheme for Robust Nonlinear Power Flow Control Using HPFC

This paper investigates the robust decentralized nonlinear control of power flow in a power system using a new configuration of UPFC. This structure comprises two shunt converters and one series capacitor called as hybrid power flow controller (HPFC). A controller is designed via control Lyapunov function (CLF) and adaptive observer to surmount the problems of stability such as tracking desired...

متن کامل

Flow field and heat transfer in a channel with a permeable wall filled with Al2O3-Cu/water micropolar hybrid nanofluid, effects of chemical reaction and magnetic field

In this study, flow field and heat transfer of Al2O3-Cu/water micropolar hybrid nanofluid is investigated in a permeable channel using the least square method. The channel is encountered to chemical reaction, and a constant magnetic field is also applied. The bottom wall is hot and coolant fluid is injected into the channel from the top wall. The effects of different parameters such as the Reyn...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014