The extent and serial pattern of interfractional variation in patients with whole pelvic irradiation: a study using a kilovoltage orthogonal on‐board imager
نویسندگان
چکیده
The purpose of this study is to assess the extent and serial pattern of setup error of conventional fractionated whole pelvic irradiation using a kilovoltage on-board imager. The daily on-board images of 69 patients were matched with the digitally reconstructed radiographs of simulation on the basis of pelvic bony structure. The shifts along x- (lateral), y- (longitudinal), and z- (vertical) axes, and the 3D vector, were measured. The shift between an origin of the first fraction and each fraction (Δshift(1st)) and the shift between an isocenter of simulation and each fraction (Δshift(Sim)) were calculated. To evaluate serial changes, the shifts of each fraction were classified into four consecutive sessions, and an ANOVA and chi-square test were used. The systematic error of the Δshift(Sim) and Δshift(1st) were 2.72 and 1.43 mm along the x-axis, 2.98 and 1.28 mm along the y-axis, and 4.26 and 2.39 mm along the z-axis, respectively. The Δshift(Sim) and Δshift(1st) ≥ 5 mm of the 3D vector occurred in 54.3% and 23.1%, respectively. The recommended margins to cover setup error in case of using Δshift(1st) were 3.81, 3.54, and 6.01 mm along x-, y-, and z-axes, whereas those using Δshift(Sim) were 6.39, 6.95, and 9.95 mm, respectively. With the passage of time, the Δshift(1st) ≥ 5 mm of 3D vector and along any axis in supine setup increased from 14.1% for first session to 22.5% for fourth session (p=0.027) and from 10.8% to 18.5% (p = 0.034), respectively. In prone setup, first session was better than others in the Δshift(1st) ≥ 5 mm of 3D vector and along any axis. It is expected that the correction using the on-board images on the first fraction improves geometrical uncertainties and reduces the margin for target coverage. Daily continuous OBI follow-up during conventional fractionated pelvic irradiation can increase the reproducibility and be more effective in the late period.
منابع مشابه
The Impact of Residual Geometric Inaccuracies on Normal Organ Doses in Image Guided-Radiation Therapy of Prostate Cancer Using On-Board Kilovoltage Cone-Beam Computed Tomography
Introduction: The aim of this retrospective study was to evaluate the variations in delivered dose to the bladder, rectum, and femoral heads of prostate cancer patients during a course of treatment by image-guided radiation therapy (IGRT). Materials and Methods: Overall, 15 patients with prostate cancer were selected and. Each week, for each patient five consecutive cone beam computed tomograph...
متن کاملUsing an onboard kilovoltage imager to measure setup deviation in intensity‐modulated radiation therapy for head‐and‐neck patients
The purpose of the present study was to use a kilovoltage imaging device to measure interfractional and intrafractional setup deviations in patients with head-and-neck or brain cancers receiving intensity-modulated radiotherapy (IMRT) treatment. Before and after IMRT treatment, approximately 3 times weekly, 7 patients were imaged using the Varian On-Board Imager (OBI: Varian Medical Systems, Pa...
متن کاملI-45: Advance MRI Sequences in Pelvic Endometriosis
Background: To assess MRI in diagnosing endometriotic lesions, emphasizing T2*weighted imaging efficacy. Materials and Methods: This prospective study of 48 females (22-38 years, average 29.6) clinically suspected of endometriosis from September 2009 to April 2012. MRI was performed with a 1.5 T imager (Siemens) with a body array coil. T1, T2 and T2* weighted (2D-FLASH) sequences were obtained ...
متن کاملPost-operative radiotherapy of keloids. A 10-years experience of kilovoltage irradiation
Background: Keloids are benign fibrous dermal tumors originating from skin injury after surgery, piercing or others wounds. Materials and Methods: Sixty-two patients with keloids were treated postoperatively using orthovoltage irradiation. The total dose delivered was 12 Gy in three consecutive days, 4Gy per fraction. Treatment started 24 h after surgery. The median follow-up was 44.5 months. R...
متن کاملChest-wall irradiation by kilovoltage x-rays: Observed local control rate versus predicted radiobiological tumor control probability
Introduction: The high local control rates observed in patients with breast cancer who had been treated by modified radical mastectomy, chemotherapy and chest-wall irradiation using 120 kV X-rays (50 Gy in 25 fractions) motivated us to investigate their observed tumor control probability (TCP) and test a well-established radiobiological TCP model against our data. Mat...