Economic outcomes of implantable cardioverter-defibrillators.

نویسندگان

  • M S Stanton
  • G K Bell
چکیده

BACKGROUND We reviewed the literature pertaining to the cost-effectiveness of implantable cardioverter-defibrillator (ICD) therapy in the management of ventricular fibrillation and tachycardia. Discussed are the methodology, advantages, and limitations of economic-outcomes analyses as related to ICD therapy; the impact of new technology and physician practice patterns; and methodological recommendations for future studies. METHODS AND RESULTS Articles published between 1990 and 1997 were screened for cost-effectiveness analyses of ICD versus antiarrhythmic drug therapy. Randomized clinical trials, prospective and retrospective studies, and economic models were included. These studies report incremental cost-effectiveness ratios ranging from cost savings of $13 975 per life-year saved (LYS) to an incremental cost of $114 917 per LYS for ICD therapy. Differences were due to study type, cost-reporting methodology, ICD technology used, and length of follow-up. Assuming current technology and physician practice patterns, we find that ICD total therapy costs may break even in 1 to 3 years. CONCLUSIONS Recent literature suggests that ICDs are a cost-effective therapy for management of life-threatening ventricular tachyarrhythmias. The advent of new technology and patient management practices should further improve the cost-effectiveness of ICD therapy. Future studies of ICD cost-effectiveness should address the implications of truncated follow-up periods and quality of life.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implantable cardioverter defibrillator during laser transurethral resection of the prostate

  Implantable cardioverter defibrillators have been instrumental in the health and safety of patients who are at increased risk of sudden death by ventricular tachycardia or fibrillation. Consensus on the perioperative management of cardiovascular implantable electronic devices has suggested that certain surgical interventions (including transurethral resection of the prostate) may interfere wi...

متن کامل

Cost-effectiveness of implantable cardioverter-defibrillators

Modelling A Markov model was constructed to simulate the clinical and economic outcomes associated with ICD and control therapy. The model served also to extrapolate short-term trial-based results to a lifetime horizon. The cycle length was one month. Patients who received an ICD were at risk of death from the implantation procedure. Patients who did not die from the procedure and patients assi...

متن کامل

Subcutaneous Versus Transvenous Implantable Defibrillator Therapy

Fro of D Re Hu an Me rec Me rel Ma OBJECTIVES This study aims to conduct a meta-analysis comparing efficacy and safety outcomes between subcutaneous implantable cardioverter-defibrillator (S-ICD) and transvenous implantable cardioverter-defibrillator

متن کامل

Programming implantable cardioverter/defibrillators and outcomes

Implantable cardioverter-defibrillators are complex technical devices with a multitude of programming options for the physician. In recent years, numerous randomized trials have been performed to define the optimal programming strategies and have provided valuable insights, especially in primary prevention patients. This article provides an actual overview on the existing evidence on the most i...

متن کامل

Incidence and Costs Related to Lead Damage Occurring Within the First Year After a Cardiac Implantable Electronic Device Replacement Procedure.

BACKGROUND Inadvertent damage to leads for transvenous pacemakers, implantable cardioverter-defibrillators, and cardiac resynchronization therapy defibrillators is an important complication associated with generator-replacement procedures. We sought to estimate the incidence and costs associated with transvenous lead damage following cardiac implantable electronic device replacement. METHODS ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 101 9  شماره 

صفحات  -

تاریخ انتشار 2000