Hybrid adiabatic-rectangular pulse train for effective saturation of magnetization within the whole heart at 3 T.
نویسندگان
چکیده
Uniform T(1)-weighting is a major challenge for first-pass cardiac perfusion MRI at 3 T. Previously proposed adiabatic amplitude of radiofrequency field (B(1))-insensitive rotation (BIR-4) pulse and standard and tailored pulse trains of three nonselective pulses have been important developments but each pulse has limitations at 3 T. As an extension of the tailored pulse train, we developed a hybrid pulse train by synergistically combining two nonselective rectangular radiofrequency pulses and an adiabatic half-passage pulse, in order to achieve effective saturation of magnetization within the heart, while remaining within clinically acceptable specific absorption rate limits. The standard pulse train, tailored pulse train, hybrid pulse train, and BIR-4 pulse train were evaluated through numerical, phantom, and in vivo experiments. Among the four saturation pulses, only the hybrid pulse train yielded residual magnetization <2% of equilibrium magnetization in the heart while remaining within clinically acceptable specific absorption rate limits for multislice first-pass cardiac perfusion MRI at 3 T.
منابع مشابه
Saturation pulse design for quantitative myocardial T1 mapping
BACKGROUND Quantitative saturation-recovery based T1 mapping sequences are less sensitive to systematic errors than the Modified Look-Locker Inversion recovery (MOLLI) technique but require high performance saturation pulses. We propose to optimize adiabatic and pulse train saturation pulses for quantitative T1 mapping to have <1 % absolute residual longitudinal magnetization (|MZ/M0|) over ran...
متن کاملSpatial Modulation of Magnetization for Cardiac Tagging Using Sinc Modulated RF Pulse Train
MRI myocardial tagging offers a tremendous opportunity to quantitatively, serially and noninvasively examine the intramyocardial motion and deformation [l-51. The ideal presaturation or tagging stripe should be of rectangular intensity profile and controllable width with respect to the distance between adjacent stripes. Here we propose a sinc modulated RF pulse train that offers sharper-edged t...
متن کاملOptimization of pulsed saturation for CEST imaging in standard clinical MR scanners
Introduction: Chemical Exchange Saturation Transfer (CEST) provides a new type of contrast for MR imaging. Recently, different saturation and readout schemes have been proposed for CEST imaging with the purpose to maximize the effect [1-3]. Especially in clinical applications, hardware limitations or safety regulations restrict full exploitation of the potential of CEST. In particular the pulse...
متن کاملOptimized saturation pulse rrains for SASHA T1 mapping at 3T
Background SASHA and MOLLI T1 mapping sequences can have errors in calculated T1 values when their magnetization preparation pulses do not fully saturate/invert magnetization [1,2]. The commonly used 90°-90°-90° saturation pulse train [3] has poor performance at 3T due to large B1 field inhomogeneities. We propose that a new hard RF pulse train with numerically optimized flip angles [4] will of...
متن کاملEvaluating exchange processes in the human brain: magnetization transfer vs adiabatic rotating frame relaxation methods
Introduction Exchange processes of bulk water protons with the protons contained in the macromolecules of tissue can be investigated with magnetization transfer (MT) experiments, which rely on saturating the “solid” pool by placing a preparation pulse (typically a continuous-wave (CW) pulse) several kHz offresonance from water [1]. Since the frequency of the off-resonance pulse does not have a ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Magnetic resonance in medicine
دوره 62 6 شماره
صفحات -
تاریخ انتشار 2009