Broken Wires, Dropped Devices, Stuck Stents, Lost Coils and rings! Surgery for device related complications of PCI

نویسندگان

  • Jayakrishnan A Gosalakkal
  • Suraj Chavan
چکیده

Background/Introduction Percutaneous interventions for cardiac disease are on the increase worldwide. Acute complications of interventions include vessel dissection, total occlusion, thrombosis etc. Other than the complications associated with the disease process and the disturbances to the vascular endothelium mechanical complications due to mishandling of or mishaps with the device itself can occur. These complications, though rare do occur and the cardiac surgeon has to deal with them often on an emergency basis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

How has the nationwide use of off-label experimental endovascular devices been allowed for two decades as first choice and sometimes the only alternative to conventional standard and advanced surgical techniques?

Dear Sir, I attended the one‐day symposium on “Cutting‐Edge and Future technology in Ischemic and Hemorrhagic Stroke” at the Congress of Neurological Surgeons 2014, Boston, MA, USA. I expected to learn about the advances in treatment of cerebro‐vascular accidents and “cures” for ischemic and hemorrhagic strokes. Instead, presenters focused on “the ways to place and navigate ‘off‐label’ devices ...

متن کامل

Percutaneous left ventricular assist device to support PCI of unprotected left main coronary artery disease

Although percutaneous coronary intervention (PCI) has long surpassed coronary artery bypass grafting (CABG) as the most common revascularization strategy in patients with coronary artery disease [1], left main coronary artery disease (LMCD) is regarded a relative contraindication to PCI [2]. This lack of enthusiasm was related to studies showing that although balloon angioplasty was effective i...

متن کامل

Intrapelvic Protrusion of a Broken Guide Wire Fragment during Fixation of a Femoral Neck Fracture

Breakage of DHS guide wire during surgery and its migration into the pelvis through the hip joint is a rare complication and its removal can be very challenging for the surgeon. We share our experience of a similar case wherein we used an ‘iliofemoral’ approach to successfully remove the broken transfixing guidewire from the hip joint. Although iliofemoral approach is similar to the lateral win...

متن کامل

Virtual Reality Training In Interventional Radiology: The Johns Hopkins and Kent Ridge Digital Laboratory Experience

This article describes a personal computer-based system for simulation of image-guided cardiovascular interventional procedures for physician and technician training, education, patient-specific pretreatment planning, and therapeutic device design and evaluation. The system provides users with the ability to manipulate and interface interventional devices such as catheters, guide wires, stents,...

متن کامل

My stent is better than your stent...Or is it?

Before coronary stents, balloon angioplasty was limited by arterial dissection, acute closure, Q-wave myocardial infarction (MI), a 5% risk for emergency coronary artery bypass graft surgery, the need for repeat procedures to treat restenosis, and sometimes procedural death. Coronary stents immediately reduced those major procedural complications. The current debates about asymptomatic periproc...