SSFP-based MR thermometry.
نویسندگان
چکیده
Of the various techniques employed to quantify temperature changes by MR, proton resonance frequency (PRF) shift-based phase-difference imaging (PDI) is the most accurate and widely used. However, PDI is associated with various artifacts. Motivated by these limitations, we developed a new method to monitor temperature changes by MRI using the balanced steady-state free precession (balanced-SSFP) pulse sequence. Magnitude images obtained with the SSFP pulse sequence were used to find the PRF shift, which is proportional to temperature change. Spatiotemporal temperature maps were successfully reconstructed with this technique in gel phantom experiments and a rabbit model. The results show that the balanced-SSFP-based method is a promising new technique for monitoring temperature.
منابع مشابه
Fast frequency mapping with balanced SSFP: theory and application to proton-resonance frequency shift thermometry.
A method is presented for the rapid acquisition of frequency maps based on multiecho balanced steady-state free precession (balanced SSFP, fast imaging with steady precession (True FISP), fast imaging employing steady-state excitation (FIESTA), or balanced fast field echo (FFE)). This technique was applied to measure temperature changes within a gel phantom based on the temperature-sensitive wa...
متن کاملSignal formation in echo-shifted sequences.
Echo shifted (ES) gradient-recalled echo sequences (whose TE > TR) have found important applications in fMRI and MR thermometry since their introduction. The technique increases T *(2) weighting in BOLD imaging and temperature change sensitivity in phase-based temperature imaging compared to FLASH sequences. Yet, inconsistent observations have previously been reported when variants of this tech...
متن کاملImproved k-space-based MR thermometry by joint PRF phase shift and T1/T2* attenuation estimation
Background/introduction MR temperature mapping based on the proton resonance frequency (PRF) shift is used in MR-guided focused ultrasound procedures for dosimetry and safety monitoring. While conventional PRF-shift thermometry is based on calculating a phase difference between two reconstructed MR images, Gaur et al [1,2] have recently described two algorithms that estimate temperatureinduced ...
متن کاملReal-time MR-thermometry and dosimetry for interventional guidance on abdominal organs.
The use of proton resonance frequency shift-based magnetic resonance (MR) thermometry for interventional guidance on abdominal organs is hampered by the constant displacement of the target due to the respiratory cycle and the associated thermometry artifacts. Ideally, a suitable MR thermometry method should for this role achieve a subsecond temporal resolution while maintaining a precision comp...
متن کاملTreatment envelope evaluation in transcranial magnetic resonance-guided focused ultrasound utilizing 3D MR thermometry
BACKGROUND Current clinical targets for transcranial magnetic resonance-guided focused ultrasound (tcMRgFUS) are all located close to the geometric center of the skull convexity, which minimizes challenges related to focusing the ultrasound through the skull bone. Non-central targets will have to be reached to treat a wider variety of neurological disorders and solid tumors. Treatment envelope ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Magnetic resonance in medicine
دوره 52 4 شماره
صفحات -
تاریخ انتشار 2004