Test of a resistive plate lNSti ? UMENIS
نویسندگان
چکیده
منابع مشابه
Cosmic Ray Studies for the Development of a Test Stand for Resistive Plate Counters
Properties of cosmic ray muons including their flux at sea level and the East-West asymmetry are studied. While these properties have been measured well in previous experiments, it has been beneficial to study cosmic ray as it has led to the optimization of our test stand performance and the development of analysis tools required in later testing of the resistive plate counters.
متن کاملBeam Test Results on Resistive Plate Chambers for the CMS Experiment
Resistive Plate Chambers were tested in a muon and a pion beam to study the performances at different running conditions. Results on a first chamber built without the linseed oil treatment of the bakelite surfaces are presented together with an evaluation of the local effects due the spacers. These results are extrapolated to the conditions expected at LHC.
متن کاملAdvances in gaseous time-of-flight detectors
Timing Resistive Plate Chambers (RPCs) are planar gaseous detectors made with a combination of metallic and resistive electrodes, delivering time resolutions around 50 ps σ and efficiency up to 99% for MIPs. In this work we describe the development and test of an electrically shielded timing RPC array for crosstalk-free time measurements in high granularity time-of-fight (TOF) systems, as the I...
متن کاملCosmic ray test results on resistive plate chamber for the BESIII experiments
A cosmic ray test system has been built to fully qualify the resistive plate chambers for the MUON system of the BESIII experiment. The setup has been designed to measure detector’s performance and to verify the stability and reliability of the MUON system. The same electronics, similar readout method and data analysis for BESIII MUON system have been used for this station. With this station, t...
متن کاملResistive Plate Chambers in ATLAS
The ATLAS first level muon trigger is based, in the rapidity region ( v ( 5 1.05, on fast and finely segmented gaseous detectors, Resistive Plate Chambers (RPCs) . A prototype of a small scale RPC trigger tower has been assembled and tested. We present results on efficiency, time resolution, cluster size and collected charge. The detectors, filled with a non-flammable and environment-safe gas m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 1994