An endothelial cell compatible biosensor fabricated using optically thin indium tin oxide silicon nitride electrodes.

نویسندگان

  • Chang K Choi
  • Anthony E English
  • Seung-Ik Jun
  • Kenneth D Kihm
  • Philip D Rack
چکیده

This study describes the fabrication and performance of an endothelial cell compatible, optically thin, indium tin oxide (ITO) microimpedance biosensor. The biosensor was constructed by sputtering a thin insulating layer of silicon nitride (Si(3)N(4)) onto a 100 nm thick ITO layer. Indium tin oxide electrodes were formed by chemically etching 250 or 500 microm diameter holes through the Si(3)N(4) insulating layer. The exposed ITO electrode was electrically connected to an ITO counter electrode, approximately 2 cm(2) in area, via a 400 microL well containing cell culture media. A lock-in amplifier circuit monitored the impedance of porcine pulmonary artery endothelial cells (PPAECs) cultivated on the electrodes as a function of frequency, between 10 and 100 kHz, and as a function of time, at 5.62 kHz. The ITO-Si(3)N(4) microelectrodes provided consistent and repeatable impedance measurements to the attachment and spreading of PPAECs. In addition, the ITO-Si(3)N(4) electrodes were recyclable, robust, resistant to ethanol sterilization, and had a high optical transmittance. Most importantly, the ITO-Si(3)N(4) electrodes allowed optical access for dynamic cellular attachment imaging. The 5.62 kHz time dependent cellular impedance response to the drug Cytochalasin D further demonstrated the feasibility of using this electrode configuration for dynamic cellular impedance studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optoelectric biosensor using indium-tin-oxide electrodes.

The use of an optically thin indium-tin-oxide (ITO) electrode is presented for an optoelectric biosensor simultaneously recording optical images and microimpedance to examine time-dependent cellular growth. The transmittance of a 100 nm thick ITO electrode layer is approximately the same as the transmittance of a clean glass substrate, whereas the industry-standard Au(47.5 nm)/Ti(2.5 nm) electr...

متن کامل

Opto-Electric Cellular Biosensor Using Optically Transparent Indium Tin Oxide (ITO) Electrodes

Indium tin oxide (ITO) biosensors are used to perform simultaneous optical and electrical measurements in order to examine the dynamic cellular attachment, spreading, and proliferation of endothelial cells (ECs) as well as cytotoxic effects when exposed to cytochalasin D. A detailed description of the fabrication of these sensors is provided and their superior optical characteristics are qualit...

متن کامل

Fabrication and characterization of combined metallic nanogratings and ITO electrodes for organic photovoltaic cells

Organic photovoltaic devices are interesting alternatives to conventional silicon based photovoltaic cells, due to potentially lower material costs and energy consumption during the fabrication process. However, the energy conversion efficiency of organic photovoltaic cells may still be improved. One possible approach is a combination with metallic nanostructures to improve light absorption pro...

متن کامل

A MICRO-FABRICATED PLANAR HIGW- ENT IrOx STIMULATING MICROELECT

This paper describes the development and presents test results of a thin-film, high-current density, iridium oxide (IrOx) microelectrode for neuromuscular stimulation. The electrode is made of a silicon substrate with polysilicon lines as the interconnect and Irox as the electrode material. The polysilicon lines are protected from body fluids by silicon dioxide and silicon nitride. The electrod...

متن کامل

Cell-compatible array of three-dimensional tip electrodes for the detection of nitric oxide release.

An array of electrodes on which cells could be grown directly was fabricated using silicon anisotropic etching and a thick-photoresist process and employed for the detection of nitric oxide (NO) released from a population of adherently growing human umbilical vein endothelial cells (HUVEC). The electrodes are tip-shaped and are 40 microm high of which only the top 15 microm are exposed Pt-tips....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biosensors & bioelectronics

دوره 22 11  شماره 

صفحات  -

تاریخ انتشار 2007