A Versatile Optical Neuronavigator System for Intraoperative MRI

نویسندگان

  • John KOIVUKANGAS
  • Sanna Kristiina YRJÄNÄ
  • Jani KATISKO
  • Veijo UKKOLA
  • Juho TUOMINEN
  • Timo KUMPULAINEN
  • Esa HEIKKINEN
  • Eero ILKKO
  • Eila SONKAJÄRVI
  • Jaakko HEIKKILÄ
  • Mika YLIHAUTALA
  • Erkki VAHALA
چکیده

John KOIVUKANGAS1, Sanna Kristiina YRJÄNÄ1, Jani KATISKO1, Veijo UKKOLA1, Juho TUOMINEN1, Timo KUMPULAINEN1, Esa HEIKKINEN1, Eero ILKKO2, Eila SONKAJÄRVI3, Jaakko HEIKKILÄ1, Mika YLIHAUTALA4, Erkki VAHALA4 1Oulu Clinic for Neurosurgery and Neurosurgical Research Unit, Kajaanintie 50, Oulu, FINLAND; 2Department of Diagnostic Radiology, Oulu University Hospital, Oulu, FINLAND; 3Department of Anesthesiology, Oulu University Hospital, Oulu, FINLAND; 4Marconi Medical Systems Finland, Äyritie 4, Vantaa, Finland;

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

W3: Intra-Operative Imaging and Brain Pathology

The Intraoperative MRI is of great importance in the surgical removal of gliomas or cranial base tumors. However, the sole use of a intraoperative MRI is problematic, so that a dual system has been developed to optimize the utilization of the equipment, which can be used both for neurosurgical patients and for outpatient or stationary Patients. Within the framework of the new head Center at the...

متن کامل

Development of an Advanced Optical Coherence Tomography System for Radiation Dosimetry

Introduction: According to the literature, optical coherence tomography (OCT) can be used measure radiation absorbed dose. This study was carried out to design a computed tomography system for the calculation of absorbed dose and optimization of dose delivery in radiotherapy using gel dosimeters. Material and Methods: An advanced charge-coupled device based OCT system was developed in laborator...

متن کامل

Framework and Bio-Mechanical Model for a Per-Operative Image-Guided Neuronavigator Including ‘Brain-Shift’ Compensation

In this paper we present a methodology to adress the problem of brain tissue deformation referred to as ”brainshift”. This deformation occurs throughout a neurosurgery intervention and strongly alters the accuracy of the neuronavigation systems used to date in clinical routine which rely solely on preoperative patient imaging to locate the surgical target, such as a tumour or a functional area....

متن کامل

Nano-gels: A versatile nano -carrier platform for drug delivery systems: A mini review

Nowadays the application of nanotechnology in different biomedical fields such as drug delivery is increasing due to its unique advantages. With this in mind, it is widely believed that nanogels as the nanometer-sized networked polymeric particles have a considerable impact on drug delivery systems as biocompatible nanocarriers due to their unique characteristics such as high loading capacity, ...

متن کامل

Siemens primus accelerator simulation using EGSnrc Monte Carlo code and gel dosimetry validation with optical computed tomography system by EGSnrc code

Monte Carlo method is the most accurate method for simulation of radiation therapy equipment. The linear accelerators (linac) are currently the most widely used machines in radiation therapy centers. Monte Carlo modeling of the Siemens Primus linear accelerator in 6 MeV beams was used. Square field size of 10 × 10 cm2 produced by the jaws was compared with TLD. Head simulation of Siemens accele...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001