Changes to Corneal Aberrations and Vision After Monovision in Patients With Hyperopia After Using a Customized Aspheric Ablation Profile to Increase Corneal Asphericity (Q-factor).

نویسندگان

  • Romain Courtin
  • Alain Saad
  • Alice Grise-Dulac
  • Emmanuel Guilbert
  • Damien Gatinel
چکیده

PURPOSE To evaluate the visual outcomes and fourth-order Zernike spherical aberrations induced with a customized change in corneal asphericity (ΔQ) correction of presbyopia combined with monovision for hyperopic patients. METHODS Consecutive hyperopic patients who underwent presbyopic LASIK between September 2013 and July 2014 were included. For the non-dominant eyes, the aspheric ablation profile associated with a myopic refraction was planned using the Custom-Q nomogram (Alcon Laboratories, Inc., Fort Worth, TX). Uncorrected distance visual acuity (UDVA), uncorrected near visual acuity (UNVA), spherical equivalent refraction, ΔQ, and change in corneal spherical aberration coefficient (ΔC40) were analyzed. Postoperative data were collected at 1, 3, and 6 months. RESULTS Sixty-five patients were included. The mean age was 56.5 ± 5.7 years (range: 47 to 70 years). At the 6-month follow-up, the spherical equivalent refraction for non-dominant and dominant eyes was -1.07 ± 0.74 and 0.32 ± 0.55 diopters (D), respectively. The mean binocular UDVA was 0.01 ± 0.04 logMAR (range: -0.12 to 0.30 logMAR); 91% of patients achieved 20/20 or better binocular UDVA and 83% of patients had Jaeger 3 (Parinaud 4) or better binocular UNVA. The ΔQ for non-dominant and dominant eyes was -0.61 ± 0.15 and -0.33 ± 0.25, respectively, for a 6-mm pupil diameter and was significantly higher for non-dominant eyes (P < .0001). The achieved ΔC40 was -0.49 ± 0.23 µm for non-dominant eyes (for a theoretical ideal value of -0.40 µm) and -0.30 ± 0.18 µm for dominant eyes. For non-dominant eyes, the attempted ΔQ (-0.60) was close to the achieved value (-0.61 ± 0.15). CONCLUSIONS For hyperopic patients, combining the customized corneal aspheric ablation profile with monovision is safe, effective, and reproducible, inducing intended changes in corneal spherical aberrations. [J Refract Surg. 2016;32(11):734-741.].

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of anterior corneal surface asphericity modification on fourth-order zernike spherical aberrations.

PURPOSE To evaluate the theoretical influence of the change in corneal asphericity (ΔQ) on the change in fourth-order Zernike spherical aberration coefficient (ΔC(4)0) with customized aspheric refractive correction of myopia and hyperopia. METHODS The initial anterior corneal surface profile was modeled as a conic section of apical radius of curvature R0 and asphericity Q₀. The postoperative ...

متن کامل

Q-factor customized ablation profile for the correction of myopic astigmatism.

PURPOSE To compare the results of the Q-factor customized aspheric ablation profile with the wavefront-guided customized ablation pattern for the correction of myopic astigmatism. SETTING Institute for Refractive and Ophthalmic Surgery, Zurich, Switzerland. METHODS Thirty-five patients were enrolled in a controlled study in which the nondominant eye was treated with the Q-factor customized ...

متن کامل

Corneal asphericity change after excimer laser hyperopic surgery: theoretical effects on corneal profiles and corresponding Zernike expansions.

PURPOSE To determine the theoretical relationships between the changes in corneal paraxial power, asphericity, and the corresponding Zernike polynomial expansion after conventional and customized excimer laser correction of hyperopia. METHODS The initial corneal profile was modeled as a conic section of apical radius of curvature R1 and asphericity Q1. The theoretical value of the postoperati...

متن کامل

Effects of optimized photorefractive keratectomy (PRK) operation on the asphericity and high-order aberration changes

Background: Optimized is a common and important method in which aberrations are created by the device and the surgeon, but high-grade aberrations are out of the surgeon's control and are induced by the device in the patient. The aim of this study was the evaluation of out-of-control high-order aberration changes before and after PRK surgery and these impact on vision outcome. Materials and meth...

متن کامل

Analysis of customized corneal ablations: theoretical limitations of increasing negative asphericity.

PURPOSE To determine the ablation depths of customized myopic excimer laser photoablations performed to change corneal asphericity after laser in situ keratomileusis (LASIK) and photorefractive keratectomy (PRK). METHODS A mathematical model of aspheric myopic corneal laser surgery was generated. The initial corneal surface was modeled as a conic section of apical radius R(1) and asphericity ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 32 11  شماره 

صفحات  -

تاریخ انتشار 2016