Optimization of endotracheal tube cuff filling by continuous upper airway carbon dioxide monitoring.
نویسندگان
چکیده
UNLABELLED Inappropriate cuff filling is responsible for various complications related to the use of an endotracheal tube (ETT). In this study, we evaluated an objective, noninvasive method for continuous assessment of leak around the ETT cuff by monitoring carbon dioxide pressure (P(CO2) in the upper airway. P(CO2) levels were measured by capnography simultaneously between the ETT cuff and the vocal cords, at the oropharynx, and in the nares of the nose. Cuff filling was regulated by an electronic controller to achieve the minimal pressure needed to prevent CO2 leak. Feasibility of the method was assessed in a human simulator and in a porcine model. Clinical function was evaluated in 60 patients undergoing surgery, comparing the method to the standard anesthesiologist evaluation. Linear correlations were observed between the ETT cuff pressure and P(CO2) level in the human simulator (R2 = 0.954, P < 0.0001) and in the porcine model (R2 > 0.98, P < 0.0001). Iodine leak around the ETT cuff, in the porcine model, occurred only when P(CO2) levels were >2 mm Hg. In the surgery patients, the mean ETT cuff pressure determined clinically by the anesthesiologist was significantly higher than the optimal cuff pressure assessed by P(CO2) (25.2 +/- 3.6 versus 18.2 +/- 7.8 mm Hg, respectively; P < 0.001). According to these findings, optimal ETT cuff filling pressure can be identified by monitoring P(CO2) at the nares or the oropharynx. IMPLICATIONS A new, objective, noninvasive method for optimizing endotracheal tube cuff filling based on monitoring carbon dioxide levels in the upper airways can be used to identify the minimal cuff pressure necessary to eliminate leak and prevent aspiration.
منابع مشابه
Airway ultrasound to detect endotracheal tube cuff herniation
Endotracheal tube (ETT) cuff herniation is not an uncommon event in Intensive Care Units and operating rooms. The cause for this can be displacement of the tube or overinflation of ETT cuff.[1] Usually, it is noticed by the sound of gas leaking around the tube or when there is a fall in tidal volume and end-tidal carbon dioxide (CO2). Confirmation and repositioning of the ETT require direct lar...
متن کاملContinuous end-tidal carbon dioxide monitoring for confirmation of endotracheal tube placement is neither widely available nor consistently applied by emergency physicians.
OBJECTIVES To determine the availability of end-tidal CO2 measurement in confirmation of endotracheal tube placement in the non-arrest patient, and to assess its use in academic and non-academic emergency departments. METHODS Emergency physicians in the USA were surveyed by mail in the beginning of the year 2000 regarding availability at their institution of both colorimetric/qualitative and ...
متن کاملمقایسه اثر استفاده از ماسک حنجره (Laryngeal mask airway) و لوله کافدار حلقی (Cuffed pharyngeal tube) در بروز گلودرد پس از بیهوشی عمومی در بزرگسالان
Post-operative sore throat is one of the most common complications and complaints of patients after general anesthesia especially in operations that need endotracheal intubations. Its causes are: size of endotracheal tube and type of its cuff, inadequate airway humidification, trauma during intubation and suctioning, high flow of inspiratory gases, surgical manipulation of airway and adjacent o...
متن کاملThe Professional Experience of Anaesthesiologists in Proper Inflation of Laryngeal Mask and Endotracheal Tube Cuff.
OBJECTIVE Cuffs inflated to inappropriately high pressures cause ischemia, reducing tracheal mucosal blood flow, while cuffs inflated at lower pressure than necessary give rise to inadequate ventilation, aspiration of gastric contents, or extubation due to air leakage. In this study, we aimed to investigate the effect of the experience of anaesthesia staff on endotracheal tube and laryngeal mas...
متن کاملImpending Complete Airway Obstruction from a Reinforced Orotracheal Tube: a Case Report.
Reinforced tubes are commonly used to minimize the opportunity of upper airway obstruction in patients at risk. There are a few reports of the airway obstruction resulted from kinked reinforced tubes. This report describes the obstruction of a reinforced tube in an adult patient who underwent tonsillectomy. Under general anesthesia; an armoured endotracheal tube was inserted into the trachea un...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Anesthesia and analgesia
دوره 101 4 شماره
صفحات -
تاریخ انتشار 2005