Determination of time-varying pressure field from phase contrast MRI data

نویسندگان

  • Lucian M Itu
  • Puneet Sharma
  • Mehmet A Gulsun
  • Viorel Mihalef
  • Ali Kamen
  • Andreas Greiser
چکیده

Methods We propose a numerical framework for determining pressure field in large arteries, the main components of which are: axi-symmetric 1-D unsteady wave-propagation model with elastic walls and an optimization framework for model personalization via parameter estimation from measured flow and anatomical data (Fig 1). 4D PC MRI data was acquired using a multi-slice phase contrast FLASH cine sequence with 3d velocity encoding (Siemens Magnetom Verio, temporal resolution 52 ms, matrix 100x192, FOV 319x219 mm, slice thickness 5 mm) in a sagittal to coronal slice orientation. Siemens 4D Flow WIP software was used for background phase, motion and venc anti-aliasing corrections, extracting vessel models including centerline trees and lumen boundary, and for automated extraction of flow profiles and cross-sectional areas. We use a linear elastic model for the vessel wall, with an axially varying stiffness. The parameters of the material model are estimated by a numerical optimization procedure, wherein the simulated deformation is fitted to the observed deformation of the vessel wall extracted from the MR data. Unsteady flow rate at the aortic inlet is extracted from PC-MRI data and used as the inlet boundary condition. To obtain physiologically valid mean and pulse pressure values and the wave propagation effects, we use a structured tree outflow boundary condition, wherein a morphological or fractal vessel tree is introduced to model the downstream behavior at the outlets of the vessel tree. The parameters for the outlet boundary condition are then independently perturbed at each individual outlet in order to match the measured unsteady outflow rate from PC-MRI data. This is achieved by adapting the final radius at which the asymmetric binary tree is terminated. The hyperbolic PDEs are solved using finite differences based on 2nd-order Lax-Wendroff method. Simulations converge after 3 cycles, with a maximum relative difference of 1% in pressure and flow between 2 consecutive cycles.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Does Exposure to Static Magnetic Fields Generated by Magnetic Resonance Imaging Scanners Raise Safety Problems for Personnel?

MRI workers are occupationally exposed to static and time-varying gradient magnetic fields.  While the 24-hour time-averaged exposure to static magnetic fields is about a few mT, the maximum static field strength can be as high as 500 mT during patient setup. Over the past several years, our laboratory has performed extensive experiments on the health effects of exposure of animal models and h...

متن کامل

Dynamic Contrast Magnetic Resonance Imaging (DCE-MRI) and Diffusion Weighted MR Imaging (DWI) for Differentiation between Benign and Malignant Salivary Gland Tumors

Background: Salivary gland tumors form nearly 3% of head and neck tumors. Due to their large histological variety and vicinity to facial nerves, pre-operative diagnosis and differentiation of benign and malignant parotid tumors are a major challenge for radiologists. Objective: The majority of these tumors are benign; however, sometimes they tend to transform into a malignant form. Functional M...

متن کامل

Delayed phases of contrast MRI, can it be valuable in multiple sclerosis active phase diagnosis?

Background: Observing the enhancing plaques in magnetic resonance imaging (MRI) is one of the most valuable diagnostic modalities in confirming the diagnosis of multiple sclerosis (MS), its recurrence and for better detection of active disease. Since active lesions discovery can improve designating diffusion in time diagnosis of MS and controlling disease activity, and there is not any definite...

متن کامل

Pressure Loss Estimation of Three-Phase Flow in Inclined Annuli for Underbalanced Drilling Condition using Artificial Intelligence

Underbalanced drilling as multiphase flow is done in oil drilling operation in low pressure reservoir or highly depleted mature reservoir. Correct determination of the pressure loss of three phase fluids in drilling annulus is essential in determination of hydraulic horsepower requirements during drilling operations. In this paper the pressure loss of solid-gas-liquid three-phase fluids flow in...

متن کامل

Automatic Prostate Cancer Segmentation Using Kinetic Analysis in Dynamic Contrast-Enhanced MRI

Background: Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) provides functional information on the microcirculation in tissues by analyzing the enhancement kinetics which can be used as biomarkers for prostate lesions detection and characterization.Objective: The purpose of this study is to investigate spatiotemporal patterns of tumors by extracting semi-quantitative as well as w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2012