Mitigation of operational losses in matrix converter fed DFIG for WECS

نویسندگان

  • Haroon Ashfaq
  • Surendra Kumar Tripathi
چکیده

With the change in the wind profile, the speed of doubly fed induction generator (DFIG) of wind energy conversion system (WECS) changes from super synchronous to sub synchronous range and vice versa. DFIG is operated to generate quality power; hence, power at rotor side is controlled using matrix converter taking power from grid and feeding back power to the grid depending on the wind profile. Input voltage required to be fed to the rotor side of DFIG is always changing and depends on the speed of the available wind. During the operation when power is fed from grid to rotor of DFIG, a high-voltage stress continues across the switches of power electronic converter (PEC). In existing topologies of the matrix converter used with the DFIG in WECS, the constant voltage stress at the power electronic switch (PES) is available which causes the higher losses across the switch. This also causes common mode voltage (CMV) which leads to the over voltage stress. This may cause winding insulation damage and bearing failure of the DFIG. Furthermore, higher dv/dt of CMV raises the leakage current which causes the thermal stress and electromagnetic noise to the equipments installed near the matrix converter. In this paper, the work done is focused on the mitigation of operational losses in matrix converter fed doubly fed induction generator for wind energy conversion system. The overall loss in the matrix converter and mitigation of common mode voltage is achieved, which improves the overall efficiency and the performance of the wind energy conversion system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Active and Reactive Power Management of Wind Farm Based on a Six Leg Tow Stage Matrix Converter Controlled by a Predictive Direct Power Controller

In this paper we propose a new configuration of the wind farm connecting with an electrical grid. The proposed Wind Energy Conversion System (WECS) is based on a two stages six-leg matrix converter using to drive a two Doubly Fed Induction Machines operating at different wind speeds. Each Doubly Fed Induction Generator (DFIG) is controlled through the rotor currents using the Finite Set Model P...

متن کامل

Fuzzy logic controlled Doubly Fed Induction Generator (DFIG) for Wind Energy Conversion System using MATLAB

This paper presents the operation of doubly fed induction generator (DFIG) with Fuzzy Logic Control & an integrated active filter capabilities using grid-side converter (GSC). The main contribution of this work lies in the control of GSC using Fuzzy Logic Control (FLC) for supplying harmonics in addition to its slip power transfer. The rotor-side converter (RSC) is used for attaining maximum po...

متن کامل

Dynamic Performance Of DFIG Based WECS Under Different Voltage Sag

At the present time Doubly Fed Induction Generator (DFIG) based wind energy conversion systems are widely used for large wind power plants. DFIG offers many advantages for instance reduced rating power converter, low cost and reduced losses with the better efficiency, easy in realization of power factor correction schemes, variable speed operation and four quadrants active and reactive power co...

متن کامل

Independent Control of Active and Reactive Powers of a DFIG Based Wind Energy Conversion System by Vector Control

The paper deals with a design and implementation of a doubly fed induction generator (DFIG) wind energy conversion system (WECS) connected to the power grid. A back-to-back AC/DC/AC converter is incorporated between the stator and the rotor windings of a DFIG, in order to obtain variable speed operation. The DFIG can be controlled from sub-synchronous speed to super synchronous speed operation....

متن کامل

FPGA-based reconfigurable control for switch fault tolerant operation of WECS with DFIG without redundancy

This paper deals with reconfigurable back-to-back converter topology and control orders in Wind Energy Conversion Systems (WECS). A typical WECS with Doubly Fed Induction Generator (DFIG) in balanced conditions is concerned. Based on the classical topology, a fault tolerant converter without any redundancy has been studied. The presented fault tolerant topology allows a “five-leg” structure wit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015