BACKGROUND Mammographic density is one of the strongest risk factors for breast cancer. It is commonly measured by an interactive threshold method that does not fully use information contained in a mammogram. An alternative fully automated standard mammogram form (SMF) method measures density using a volumetric approach. METHODS We examined between-breast and between-view agreement, reliability, and associations of breast cancer risk factors with the threshold and SMF measures of breast density on the same set of 1,000 digitized films from 250 women who attended routine breast cancer screening by two-view mammography in 2004 at a London population-based screening center. Data were analyzed using random-effects models on transformed percent density. RESULTS Median (interquartile range) percent densities were 12.8% (5.0-22.3) and 21.8% (18.4-26.6) in the threshold and SMF methods, respectively. There was no evidence of systematic differences between left-right breasts or between views in either method. Reliability of a single measurement was lower in the SMF than in the threshold method (0.77 versus 0.92 for craniocaudal and 0.68 versus 0.89 for mediolateral oblique views). Increasing body mass index and parity were associated with reduced density in both methods; however, an increase in density with hormone replacement therapy use was found only with the threshold method. CONCLUSION Established properties of mammographic density were observed for SMF percent density; however, this method had poorer left-right reliability than the threshold method and has yet to be shown to be a predictor of breast cancer risk.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigating the Factors Affecting the Mammographic Density of Breast Tissue in Patients Referred to the Breast Cancer Research Center, Iran

Introduction: Of the factors leading to false negative results in mammography is breast tissue density, and by increasing the density of breast tissue in mammography, the mammography sensitivity decreases. On the other hand, increasing the breast tissue density leads to increased risk of breast cancer. Various factors such as inheritance, genetics, hormonal and reproductive factors, and nutriti...

متن کامل

A method to consider Non-Discretionary factors in Data Envelopment Analysis

The technique for efficiency measurement known as Data Envelopment Analysis (DEA) has been extended to allow on-discretionary inputs that affect production. Several methods exist for measuring efficiency to control these factors in production. This paper review these approaches, providing a discussion of strengths and weaknesses and highlighting potential limitations. In addition, a new approac...

متن کامل

Investigating the Factors Affecting the Mammographic Density of Breast Tissue in Patients Referred to the Breast Cancer Research Center, Iran

Introduction: Of the factors leading to false negative results in mammography is breast tissue density, and by increasing the density of breast tissue in mammography, the mammography sensitivity decreases. On the other hand, increasing the breast tissue density leads to increased risk of breast cancer. Various factors such as inheritance, genetics, hormonal and reproductive factors, and nutriti...

متن کامل

Measuring the Quadriceps Angle by a New Method and Comparison with Goniometer and Radiography

Objective: The purpose of this study is to decrease the amount of error when measuring Q–angles using a goniometer by the new method, a private system developed at the I.R;#39s university of social welfare & rehabilitation sciences (USWR) by Investigator. Materials & Methods: Fourty subjects with Eighty healthy knees participated in this methodologic study. One investigator participated in d...

متن کامل

Comparison of Singh index accuracy and dual energy X-ray absorptiometry bone mineral density measurement for evaluating osteoporosis

Background: The Singh index is an inexpensive simple method to evaluate bone density, commonly used to assess osteoporosis is based on the radiological appearance of the trabecular bone structure of the proximal femur on a plain antero-posterior (AP) radiograph. The purpose of this study was to compare between Singh index and bone mineral density measurement using dual energy X-ray abs...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Cancer epidemiology, biomarkers & prevention : a publication of the American Association for Cancer Research, cosponsored by the American Society of Preventive Oncology

دوره 16 6  شماره 

صفحات  -

تاریخ انتشار 2007